2. COLLECTOR
In
m
enu 2.Collectors, there are menus associated with configured
collector fields. Depending on the configuration, menus for 1 to max. 2
collector fields
are displayed here
2.1.
Collector 1
Menu 2.
1
, Collector 1 contains menus for setting the parameters for the
1st
Collector field.
example: configurated 2 collector fields
T MAX collector 1
140
min./max.
30 / 150
°C
unit.
2.1.1. T MAX COLLECTOR1
Set
tin of
maximum collector temperature 1.
The solar collector field 1
pump runs to the temperature in the collectors [T MAX collector 1] after
which it goes off (to protect the armature from excessive temperature
due to steam in the collectors and the inability to operate the pump until
the temperature in the collectors drops below the set max. collector).
When the temperature in the collectors drops below [T MAX Collector1 -
4°C], the Collector Field 1 pump again starts working if other conditions
are met
.
NOTE
:
[T MAX collector] it is necessary to adjust
to
the point of solar
fluid boilin
g
in the solar system and always be lower than the boiling
point.
2.1.2.
Pulse collector start
In the menu 2.1.2.
P
ulse
collector
start contains the menus for adjusting
the parameters for the pulse start pump (kick) of the collector field 1.
If the collector sensor is not mounted in the collector (
but it is set
somewhere on the flow pipe) or has more than one collector in the same
field, it is recommended to switch on the impulse
collector
start which, if
the pump collector pauses, occasionally
starts
collector pump at a
specified time to obtain a more accurate current temperature solar fluid
on the collector sensor.
NOTE:
excessive and long-lasting pump operation can be tank
unnecessarily cooled down
the tank.
Pump
working
time and
stop
depends on the size and location of the collector field and the collector
sensor.
I
I
I
User menu, sollar collector
21
Technical instructions
Cm
-SOL
Factory settings