Fuel:
Wood pellets
This submenus depend about DHW configuration
Submenus:
1. p.Maximal boiler temperature
In this submenu is possible to adjust maximal boiler working temperature.
- Factory adjusted: 80°C
- Adjustment range: 70°C - 90°C
2. p.Buffer tank temperature
In this submenu is possible to adjust buffer tank temperature.
- Factory adjusted: 80°C
- Adjustment range: 40°C - 85°C
3. p.Differential buffer tank temperature
In this submenu is possible to adjust differential for buffer tank temperature.
- Factory adjusted: 10°C
- Adjustment range: 5°C - 30°C
4. p.Differential stop buffer tank temperature
In this submenu is possible to adjust differential stop for buffer tank temperature.
- Factory adjusted: 5°C
- Adjustment range: 3°C - 30°C
TEMPERATURE ADJUSTMENT FOR WOOD PELLET FIRING
Temperature adjustment
Technical instructions
BioTec Plus
94