An example of the chimney selection:
- boiler output: 25 kW
- Fuel: wood logs, wood pellets
- required useful chimney height: H=8 m
- required inner chimney diameter: 18 cm
- boiler output: 35 kW
- Fuel: wood logs, wood pellets
- required useful chimney height: H=8 m
- required inner chimney diameter: 20 cm
- boiler output: 45 kW
- Fuel: wood logs, wood pellets
- required useful chimney height: H=8 m
- required inner chimney diameter: 22 cm
Figure 5.
- Dimensioning of the chimney for BioTec Plus boilers
Useful chimney height -
from flue gas tube connection
to the top of chimney
Inner chimney diameter -
interior chimney diameter.
Nominal thermal output of the boiler (kW)
Useful height of the chimney (m)
In
n
e
r d
ia
m
e
te
r o
f t
h
e c
h
im
n
e
y (
c
m
)
At connecting a boiler to the chimney, flue gas tubes and elbows must not pass behind the fan since in
that case the cleaning and maintenance will not be possible. An example of
incorrect
position of flue
gas tubes and elbows in relation to the fan is presented at the Figure 4.
Figure 4.
Incorrect connecting the boiler to the chimney - not possible cleaning of the fan
BioTec Plus 45
BioTec Plus 25 / 35
Fan
Flue gas elbow
Flue gas tube
Connection to the chimney