BioTec Plus
35
45
TYPE:
(kW)
(kW)
(kW)
(Pa)
(l)
(°C)
(°C)
(°C)
(°C)
(kg/s)
(kg/s)
(kg/s)
(kg/s)
(h)
(h)
(°C)
(°C/bar)
(°C)
(mbar)
(%)
(l)
(mm)
(l)
(l)
(l)
(W)
(W)
(W)
(W)
(W)
(W)
(W)
(W)
(V~)
(Hz)
(A)
(kg)
(bar)
(bar)
(°C)
(mm)
(pcs.)
(R)
(R)
(R)
(R)
25
25
12,5-25
7,5-25
138
90-170
90-130
70-110
60-110
0,019
0,0206
0,010
0,0055
3,5
-
12,8
90
1,6
10,4
80
1100
110
60
5
1100
45
30
5
5,1
750
150
8
35
17 -3
,5 5
10,2-35
167
90-170
90-130
70-110
60-110
0,022
0,030
0,012
0,0080
4
-
25,1
144
1,6
10,4
148
1100
116
68
5
1100
48
33
5
5,1
875
160
10
45
22,5-45
13,5-45
187
90-170
90-130
70-110
60-110
0,027
0,0385
0,014
0,0121
4
-
41,6
176
2,5
20,2
148
1100
122
75
5
1100
50
35
5
5,1
930
180
10
600×250×600
600×400×600
600×400×735
Boiler
connections
Flow and return pipe (male thread)
Charge/discharge (female thread)
Heat exchanger connector (male thread)
Connector of exchanger sensor (female thread)
WOOD:
A by 303-5:2012; B by EN ISO 17225-5:2014-09
WOOD PELLETS:
C1 by EN 303-5:2012; A1 by EN ISO 17225-2
Nominal heat output
Heat output range (wood)
Heat output range (wood pellets)
Boiler class (wood / wood pellets)
Required chimney underpressure
Water amount in boiler
Exhaust gas temperature at nominal heat output (wood)
Exhaust gas temperature at nominal heat output (wood pellets)
Exhaust gas temperature at minimal heat output (wood)
Exhaust gas temperature at minimal heat output (wood pellets)
Exhaust mass flow at nominal heat output (wood)
Exhaust mass flow at nominal heat output (wood pellets)
Exhaust mass flow at minimal heat output (wood)
Exhaust mass flow at minimal heat output (wood pellets)
Minimum operating time at rated power (nominal Q ) (wood)
N
Minimum operating time at rated power (nominal Q ) (wood pellets)
N
Min. inlet water tem. at the boiler supply water connection
Cold water tem. and pressure for safety heat exchanger
Setting range for temperature controller (wood / wood pellets)
Boiler resistance on water side at nominal output (dT=10°C)
Fuel moisture content
Fuel size
Fuel loading chamber capacity (wood)
Fuel loading chamber dimensions (D×W×H) (wood)
Firebox volume (wood pellets)
Combustion chamber volume (wood pellets)
Pellet tank volume
Combustion chamber type
Required minimum accumulation volume (tank) next to boiler
Maximal electrical power input (wood)
Auxiliray power requirements at Q (wood)
N
Auxiliray power requirements at Q (wood)
min
Standby power (wood)
Maximal electrical power input (wood pellets)
Auxiliray power requirements at Q (wood pellets)
N
Auxiliray power requirements at Q (wood pellets)
min
Standby power (wood pellets)
Supply voltage
Frequency
Max. electrical current
Current type
Total mass - (boiler with casing and accessories)
Max. operating overpressure
Test pressure
Max. operating temperature
Flue gas tube - external diameter
Number of turbulators
Heating appliance working
Heating appliance working
5
10
60
10-15°C / 2 bar
max. 90 / 65 - 90
max 25 % for wood, max. 12% for wood pellet
(450-550) x 70 x 50 for wood, fi6
underpressure
by EN 303:2012-point 4.4.6
230
50
~
2,5
5,5
90
6/4"
3/4"
3/8"
1/2"
with fan
under non-condensing conditions
Fuel type
Technical data
Technical instructions
BioTec Plus
3