7
2.4
Control panel
Table 2-3
Button functions
Button
Display
Button function
Select operating mode
Strip only
For testing the incision depth of the blade.
The LED on the button lights up.
Strip and crimp
The LED on the button lights up.
Changing the speed of the feeder bowl
Increases the speed of filling the feeder bowl if new end
sleeves have been filled. Display shows 100%.
The speed of the feeder bowl can be changed using the
arrow buttons. The speed is shown in percent in the
display.
2 s
Setting the counter to zero
Pressing the set/reset button for two seconds resets the
counter to zero.
5 s
Changing the counting direction
Pressing the set/rest button for five seconds changes
the counting direction. The counting direction is shown in
the display.
Forwards (1, 2, 3, ...)
Backwards (..., 3, 2, 1)
When counting backwards, a checkered flag appears at
0 items. The device can no longer be started. Turn the
EPB-1N off and on again. The EPB1-N changes to
forwards mode.
Changing the counter reading with backwards
counting
Press the set/reset button briefly to change the counter
reading. The selected number flashes.
The selected number can be changed using the plus or
minus button.
Another position within the five digit number can be
selected using the arrow buttons.