Connecting EPB-1N
•
Connect compressed air connection (1) to the compressed air
supply.
•
Check air pressure at manometer (2):
operating pressure 5 bar, at least 4.5 bar (EPB-1N)
•
Set air pressure, if necessary. Pull the air pressure regulator
(3) upwards, set the air pressure by turning (4) to the right (+)
or left (-) and then press the regulator (5) downwards.
•
Connect the mains plug to the EPB-1N mains connection
and the shock-proof plug to the mains socket.
Stripping conductors
A Stripping
Press the "Strip" button.
B Stripping and crimping
Press the "Strip and crimp" button.
Set the speed of the feeder bowl.
Wait until the end sleeve is visible at the separation plate
(1).
A and B
•
Insert the conductor straight into the insertion funnel until it
stops. As soon as the EPB-1N starts, hold the conductor
with slight tension.
The conductor is automatically stripped.
•
When the EPB-1N has stopped, pull the conductor out
.
Shutting down
•
If necessary, read the counter and reset to zero.
•
Switch off the EPB-1N with the mains switch.
4.5 bar ... 6 bar of filtered air
In the event of a malfunction or improper stripping,
see page 17.