14
5 Retrofitting
5.1
Changing the cross section
Preparing the modification
•
Switch off the EPB-1N with the mains switch (1).
•
Disconnect the mains plug (2).
•
Disconnect the compressed air connection (3).
•
Open the front door.
Retrofit kits, see page 5.
Changing the feeder bowl
•
Unscrew the winged screw (1)
•
Move the feeder bowl to the side (2), pull upwards (3) and
empty.
•
Attach the feeder bowl in such a way that it slides into the
centering pins and tighten the winged screw.
Changing the reversing base sleeve
•
Pull the release lever (1) forwards.
•
Remove the reversing base sleeve (2) downwards.
•
Hold the release lever in the forward position and attach the
reversing base sleeve with the desired cross section.
•
Lock the release lever into place.
WARNING: Risk of injury!
Disconnect the mains plug and the compressed air
before you open the front door!
Change the feeder bowl during a cross sec- tion
change from 0.5.....1.5 ↔ 2.5
NOTE:
Ensure that all end sleeves are removed,
especially from the slot under the baffle.
Change the reversing base sleeve during a
cross section change from 0.5…1.5 ↔ 2.5.