Page 42 | 1-800-343-9463
CCM9000
101017
The User Menu is accessed by pressing and holding the SET button for 3 seconds. Use the UP and DOWN ARROW
buttons to navigate to desired parameters . Press the SET button again to view these parameters . Press the UP and
DOWN ARROW buttons to adjust a parameter .
The following parameters are available in the menu:
Parameter
Description
Fdc - humidity enhancement
This parameter is measured in minutes, and is preset at the
factory to 1 . An increase in this parameter will increase the humidity
enhancement of your cellar . This parameter should not be adjusted
to zero . Adjustments should be made in increments of 5, with a
maximum of 15 and a minimum of 1 . After making any adjustments
to humidity enhancement, you should wait a minimum of 3 days
before making any additional adjustments . This will allow sufficient
time for the cellar to acclimate to the new setting .
FOF - “fan off”
This setting controls how long the fan stays off after the set point
has been reached . It is preset to 15 minutes . This setting should
not be adjusted, as most properly constructed wine cellars retain
an ample amount of humidity during the “fan off” cycle . If, however,
you wish to decrease the duration of the “fan off” cycle (in order to
increase the wine cellar’s relative humidity), you can adjust this
setting in the User Menu .
Fon - “fan on”
The “fan on” time is preset to zero minutes . This keeps the relative
humidity of the wine cellar at a stable level . If, however, you wish
to raise the relative humidity of your wine cellar, you can increase
the duration of the “fan on” cycle in increments of five (5, 10, or 15
minutes) . After making any adjustment to the “fan on” cycle, you
should wait a minimum of 3 days before making any additional
adjustments . This will allow sufficient time for the cellar to acclimate
to the new setting .
CA1 - bottle probe (Pb1) calibration
CA1 - bottle probe (Pb1) calibration: You may use this parameter
to calibrate the bottle probe to a known temperature . This param-
eter can be adjusted between -12°F and 12°F . For example, if the
bottle probe temperature is 58°F, and the known temperature is
55°F, you can set the CA1 parameter to -3°F to match the known
temperature .
PA2 - installer menu
This menu is only accessible using a password and is not available
for adjustment .
USER MENU