5.4 Inview S
Inview S
is an advanced monitoring and controller unit for
Bravo 25
,
Bravo 10, Sierra 25
, and
Sierra 10
power
systems. It allows the user to easily access the system information through inbuilt powerful touch screen graphic
display. In addition to the touch screen display, the user can also access the system information through the web
interface and SNMP protocol.
The Inview S interface provides the user to access the configuration and setup files of the modules in the system. Also,
it is a controller for DC regulation.
Inview S can monitor up to 32 converters/converters and featured with:
•
LCD touch screen display
•
2 Digital Inputs
•
2 Output Relay contacts
•
Records 5000 events as FIFO
5.4.1 Inview S - Connections
Inview S is composed of multiple network ports and inbuilt free potential contacts.
C
-
C
+
-
NC
+
Digital Input 2
Digital Input 1
Output Relay 2
Output Relay 1
Power 12 Vdc
NC
PE
NO
-
NO
+
CAN
iso RS485
ETH
USB
CE+T COM
•
CE+T COM
port is dedicated to establish connection between Inview S and Sierra 10 - shelf.
•
ETH
port is used for network connectivity and user can access the system information in the Web Interface.
•
CAN / iso RS485
is used share the system (DC) information to MBB (Measure Box Battery).
(Note: In future version, user can use this port for RS485-Modbus communication)
•
USB
port is used to access the Inview S configuration and setup files.
•
Digital Inputs (D1 and D2):
Two potential free Digital Inputs are available for customer connections.
Digital Input 1 is assigned for MBP operation if used.
Digital Input 2 is assigned for Surge Arrester if used.
•
Output Relays (K1 and K2)
: Two output relays are available and can be used for Major and Minor Alarms.
•
Power
: The unregulated se12 V power supply is required for powering Inview S and this power should
not be shared with other devices. (CET can provide Auxiliary Power Supply converter and the part number is
T602004120).