Содержание Sierra 10 - 48/230

Страница 1: ...otected by several international patents and trademarks Address CE T S a Rue du Charbonnage 12 B 4020 Wandre Belgium www cet power com info cet power com SIERRA 10 48 120 User Manual V1 1 THE NEW GENE...

Страница 2: ...ler Unit 15 5 3 1 Inview Slot 15 5 4 Inview S 17 5 4 1 Inview S Connections 17 5 5 Measure Box Battery MBB 18 6 System Installation 19 6 1 Transformer and Generator Sizing 19 6 2 Mounting kit for Sier...

Страница 3: ...10 41 8 1 1 Removal 41 8 1 2 Inserting 41 8 2 Controller Inview Slot 42 8 2 1 Removal 42 8 2 2 Inserting 42 8 3 Controller Inview S 43 8 3 1 Panel Mounting 43 9 Finishing 44 10 Commissioning 45 10 1 C...

Страница 4: ...4 14 4 2 Single phase L N REG 55 14 4 3 Single shelf Split phase L1 L2 N 56 14 4 4 Single shelf Split phase L1 L2 N REG 57 14 4 5 Two shelves Split phase L1 L2 N 58 14 4 6 Two shelves Split phase L1 L...

Страница 5: ...ase Note Version Release date DD MM YYYY Modified page number Modifications 1 0 07 02 2022 First release of the manual 1 1 15 09 2022 Updated the shelf connections 5 Sierra 10 48 120 VAC User Manual v...

Страница 6: ...olution that unlike most used UPS s Maximizes the operator s applications uptime Operates with lowest OPEX Provides best protection to disturbances Optimizes footprint Our systems are Modular Truly re...

Страница 7: ...LAN Local Access Network MBB Measure Box Battery MBP Manual By pass MET Main Earth Terminal MIB Management Information Base N Neutral NTP Network Time Protocol NUA Non Urgent Alarm PCB Printed Circui...

Страница 8: ...e are required to have knowledge or experience related to electrical maintenance Please follow the procedures contained in this Manual and note all the DANGER WARNING AND NOTICE marks contained in thi...

Страница 9: ...erminated with no voltage power applied de energized The safety standard IEC EN62040 1 1 requires that in the event of an output short circuit the inverter must disconnect in 5 seconds maximum The par...

Страница 10: ...ed on a system unit make sure that AC input voltage and DC input voltage are disconnected CAUTION Risk of electric shock Inverter modules and shelves contain capacitors for filtering and energy storag...

Страница 11: ...hort circuit at the AC output the converter will provide 4 x In during 20 ms to force output MCB to trip Breaker selectivity shall be adapted according to the power available Sierra module works on Tr...

Страница 12: ...r of a module can be shared between the AC load DC load and charging power based upon the requirement If the AC source is not present the module seamlessly switches to DC source without impacting the...

Страница 13: ...ierra 10 48 230 Part Number Module Shelf T711330201 T714330000 Cooling Audible noise Fan forced cooling 65db 1meter MTBF 200 000 hrs at 30 C 80 load MIL 217 F Dielectric strength DC AC 4300 Vdc RoHS C...

Страница 14: ...20 ms 34 A Short circuit current after 20 ms 16 5 A for 15 sec 12 5 A from 15 to 60 sec after 60 sec manual reset is required AC output voltage stability 1 from 10 to 100 load DC Output Data Nominal v...

Страница 15: ...shelf and reduces the additional space in the cabinet It allows the user to easily access the system information through inbuilt powerful LCD touch screen graphic display In addition to the touch scr...

Страница 16: ...Input 1 is assigned for MBP operation if used Digital Input 2 is assigned for Surge Arrester if used Output Relays K1 and K2 Two output relays are available and can be used for Major and Minor Alarms...

Страница 17: ...ay 1 Power 12 Vdc NC PE NO NO CAN iso RS485 ETH USB CE T COM CE T COM port is dedicated to establish connection between Inview S and Sierra 10 shelf ETH port is used for network connectivity and user...

Страница 18: ...composed of multiple digital inputs and analog outputs They are used for Battery management Voltage V1 to V3 Current I1 to I3 Temperature T1 and T2 Driving the Low Voltage Disconnection 8 Digital Inpu...

Страница 19: ...All cables lugs must be C UL US or CSA listed They must be sized according to the rated current of the converter system and to the customer terminal connection Wire all positions for future expansion...

Страница 20: ...Hex socket screw with Allen key till it touches behind the metal part 3 Fix the other end of the mounting kit at cabinet rear using the M6 Philips head screw and cage nut 4 Similarly assemble another...

Страница 21: ...and bottom of the protection cover Note Refer to section 14 1 page 51 to know more about knockout dimensions 3 Connect the power and signal cables with supplied screws refer section 6 4 2 page 22 for...

Страница 22: ...s 6 4 2 1 EPC Version Inview Slot Terminals Refer to section 6 4 9 page 28 DC DC AC OUT AC IN L1 PE L2 AC IN AC OUT L2 N N PE L1 Sierra 10 48 120 Shelf Rear Details 6 4 2 2 REG Version No AC In Inview...

Страница 23: ...terminals A single phase system is 120 Vac from L to N Input and output are the same consisting of 2 wires PE Ground Note The jumper cable should be a minimum of 12 AWG DC DC AC OUT AC IN L1 J1 J2 PE...

Страница 24: ...two shelves the Jumpers J1 and J2 should be present on both shelves For connection details refer to sections 14 4 5 page 58 and 14 4 6 page 59 In each phase the number of modules should be equal DC D...

Страница 25: ...elow image CET Bus and Neutral cables must be paralleled if it is multiple shelves Note In each phase the number of modules should be equal DC CET Bus cable 6 8 Pin DC Shelf 1 Shelf 2 Shelf 3 Neutral...

Страница 26: ...problem but you may infringe the local regulation L1 L2 L3 N PE Local TFO Circuit Breaker Converter UPS Model Configuration Maximum Capacity Current 120 Vac MCB per Shelf Cable Minimum S71A33CDD04SNF0...

Страница 27: ...74 A 100 A 3 AWG S71A33CDD05SNF00G00H 5 kVA 4 kW 93 A 125 A 2 AWG S71A63CDD04SNF00G00H Split Phase 3 Wires L1 L2 N 4 kVA 3 2 kW 74 A 100 A 3 AWG S71A63CDD08SNF00G00H 8 kVA 6 4 kW 2 x 74 A 2 x 100 A 3...

Страница 28: ...rt CAN 1 CAN 2 CE T COM Power Power Auxiliary Power supply kit 12 V DC CAN iso RS485 RJ45 Cable RJ45 Cable 2 3 1 To know more about Inview S terminal details refer to section 5 2 3 page 17 6 4 9 Signa...

Страница 29: ...emote ON OFF function Pin 1 3 Pin 2 3 Status Indication 1 Open Open Normal operation All Green 2 Closed Open OFF AC output OFF AC Input Green DC Input Green 3 Open Closed Normal operation All Green 4...

Страница 30: ...properly Blinking green orange alternatively Recovery mode Permanent orange Starting mode Blinking orange Modules cannot start Check Inview Blinking red Recoverable fault Permanent red Non recoverable...

Страница 31: ...and the previous screen In some screens up and down arrows appear at the top of the page indicating more contents are present 2 Status bar The status bar appears throughout the interface and illumina...

Страница 32: ...ttery DC Wi Fi Refresh module list Cut off alarms AC In details Current Voltage Hertz Active power kW Apparent Power kVA DC details Current Voltage Power AC In details Current Voltage Active power kW...

Страница 33: ...ons for next and previous page In some pages Up and Down navigation buttons appear at the right side indicating more contents are present 2 Information Area Provides information about the correspondin...

Страница 34: ...wer AC Out details Voltage Current Active power Apparent power Power factor DC details Voltage Battery current Battery power Load current Load power Battery temperature AC In details Voltage Current P...

Страница 35: ...red converters 9 Installed power It is the total power of the configured converters including redundancy Moreover it is a user configuration based upon the system capacity 10 Available power It is the...

Страница 36: ...ogy selection Administration Home Dashboard Monitoring Energy System Converter System Converter Systems DC Systems Sensors Actuators DC System Reporting Users Files Explorer CANbus Devices Dashboard S...

Страница 37: ...Mozilla Firefox Safari or Microsoft Edge Inview Slot S and X have three login Basic Expert and Admin All three login is password protected The default password for all three logins is 1234 Basic logi...

Страница 38: ...regarding AC Input 2 DC Clicking on the DC region displays the page contains all measurements regarding DC input and output 3 Power System Clicking on the Power System region display the page contains...

Страница 39: ...p and Rename icons are present at right side of the web page Filters Page displays depending upon the filter selection On Board help Provide a short description to help to know about the corresponding...

Страница 40: ...all the parameter changes in the modifications list and saves them in the configuration file Dismiss All Clicking on DISMISS ALL button the controller rejects all the parameter changes in the modific...

Страница 41: ...ltaneously pull the module using front handle 3 Remove the module from shelf and replace with a new module or dummy cover Push the pin and pull the module Remove the module from shelf Insert the pin i...

Страница 42: ...e the module from shelf Insert the pin into the hole Pin Hole 8 2 2 Inserting 1 Place the Inview Slot and slide into the shelf 2 Push the unit firmly until the controller rear part is engaged correctl...

Страница 43: ...four latches at the rear side of the Inview S in the panel sheet 3 Connect required connection cables to the Inview S 4 Place the panel sheet in the system and fix it with screws Place the Inview S i...

Страница 44: ...ables are strained relived Make sure that all breakers are according to recommendation and local regulations Make sure that DC polarity is according to marking Re tighten all electrical terminations M...

Страница 45: ...o have all module operating when running on DC and have module failure when AC input recover from fault condition Installation and commissioning must be done and conducted by trained people fully auth...

Страница 46: ...according to the site LVD load on AC AC threshold level Switch OFF ACin and check if system is working on DC Switch ON ACin and check if system correctly transferred load on AC Switch OFF system and s...

Страница 47: ...t Check that Inview is present and properly connected Check remote ON OFF terminal Check the configuration and setting Check threshold level Converter only run on AC or DC Check AC input present and i...

Страница 48: ...idelines may be requested by email at tech support cetamerica com The RMA number should be mentioned on all shipping documents related to the repair Be aware that products shipped back to CE T Power w...

Страница 49: ...ature deviation may indicate build up of dust Clean the module by air suction blower or vacuum cleaner Check module system load Check Correct inverter mapping DC group AC group Address Change configur...

Страница 50: ...27 or tech support cetamerica com Normal service hours are 8 00 AM to 5 00 PM Eastern Time Monday through Friday except closing periods for holidays or inclement weather Critical emergency conditions...

Страница 51: ...50 Le Side View 14 1 2 Shelf 484 44 30 C FRONT VIEW 496 45 501 52 522 75 442 85 35 26 50 75 TOP VIEW 43 50 496 45 LEFT VIEW RIGHT VIEW 27 86 15 90 DETAIL A SCALE 1 2 34 90 22 20 DETAIL B SCALE 1 2 126...

Страница 52: ...1 D7 D6 V2 V1 V3 I2 I3 T1 T2 D1 D2 D3 D4 D8 POWER 0 5 OUT OF THE SYSTEM 12Vaux 0Vaux 12 V From Shunt aux 0 Vaux A X8 LAN 0 5 A V1 V1 0 5 Blk 3 6 MAJOR ALARM MINOR ALARM REMARKS X9 2 3 CLOSE IN CASE OF...

Страница 53: ...2 D3 D4 D8 POWER 0 5 OUT OF THE SYSTEM 12Vaux 0Vaux A3 0 5 A I1 I1 VBAT VBAT Aux12V_C Aux12V_NO V V K LVD BLACK RED K LVD AUX 1 2 3 4 5 6 8 MAJOR ALARM MINOR ALARM PINK GR EY YE LL OW GR EEN B RO WN W...

Страница 54: ...E USED 2 DC DC DC INPUT 1 48VDC 4AWG 25MM2 2AWG 35MM2 3 L N PE L N PE AC OUTPUT 120VAC AC INPUT 120VAC 4AWG 25MM2 2 NO NC C NO NC C DIG IN RELAY 2 RELAY 1 INVIEW S SLOT D2 C D1 8 6 L1 L1 X1 X6 X96 L1...

Страница 55: ...TPUT 120VAC 4AWG 25MM2 2AWG 35MM2 3 8 6 L1 L1 X1 X6 X96 L1 L1 X91 X94 X4 X8 X95 DC AC OUT AC IN RACK 1 BRAVO SIERRA 10 L2 L2 L2 L2 N N 1 2 3 X5 RI O 2 AC OUTPUT L1 L2 INTERLINK CONNECTION 1 REG MODE M...

Страница 56: ...C NO NC C DIG IN RELAY 2 RELAY 1 INVIEW S SLOT D2 C D1 8 6 L1 L1 X1 X6 X96 L1 L1 X91 X94 X4 X8 X95 DC AC OUT AC IN 4 MODULES INSTALLABLE RACK 1 BRAVO SIERRA 10 L2 L2 L2 L2 N N 1 2 3 X5 RI O N PE L1 L...

Страница 57: ...VDC 2AWG 35MM2 3 8 6 L1 L1 X1 X6 X96 L1 L1 X91 X94 X4 X8 X95 DC AC OUT AC IN 4 MODULES INSTALLABLE RACK 1 BRAVO SIERRA 10 L2 L2 L2 L2 N N 1 2 3 X5 RI O L1 L2 AC OUTPUT 2x120 208VAC 2x120 240VAC 10AWG...

Страница 58: ...N N 1 2 3 X5 RI O 2 2 N PE L1 L2 AC OUTPUT 2x120 208VAC 2x120 240VAC N PE L1 L2 AC INPUT 2x120 208VAC 2x120 240VAC DC DC DC DC DC INPUT 1 2 48VDC 2AWG 35MM2 8 6 L1 L1 X1 X6 X96 L1 L1 X91 X94 X4 X8 X9...

Страница 59: ...ACK 1 BRAVO SIERRA 10 L2 L2 L2 L2 N N 1 2 3 X5 RI O 2 2 N PE L1 L2 AC OUTPUT 2x120 208VAC 2x120 240VAC DC DC DC DC DC INPUT 1 2 48VDC 2AWG 35MM2 8 6 L1 L1 X1 X6 X96 L1 L1 X91 X94 X4 X8 X95 AC OUT AC I...

Страница 60: ...BRAVO SIERRA 10 L2 L2 L2 L2 N N 1 2 3 X5 RI O 2 2 N PE N PE 8 6 L1 L1 X1 X6 X96 L1 L1 X91 X94 X4 X8 X95 AC OUT AC IN 4 MODULES INSTALLABLE RACK 2 BRAVO SIERRA 10 L2 L2 L2 L2 N N DC 4AWG 25MM2 DC DC DC...

Страница 61: ...LES INSTALLABLE RACK 1 BRAVO SIERRA 10 L2 L2 L2 L2 N N 1 2 3 X5 RI O 2 2 N PE 8 6 L1 L1 X1 X6 X96 L1 L1 X91 X94 X4 X8 X95 AC OUT AC IN 4 MODULES INSTALLABLE RACK 2 BRAVO SIERRA 10 L2 L2 L2 L2 N N DC 4...

Страница 62: ...se 1 1 1 4 CF123 Nominal Phase Shift The angle of phase shift at phase 1 0 0 240 Deg CF124 Nominal Voltage The nominal voltage at AC output of phase 1 100 120 130 V CF141 Configured Converters The num...

Страница 63: ...er 80 138 144 V CF1011 High Stop AC IN Voltage where a higher value leads to stop the AC IN converter 80 138 144 V CF1012 Low Start Frequency where a higher value leads the outlet of the converters tr...

Страница 64: ...ort circuit after this time the output will be stopped 1 10 600 s CF1036 Input source in Percent Defines the priority source 0 Feeding from AC IN has priority converter AC AC EPC mode default value 10...

Страница 65: ...op 0 0 1 CF1048 Airco Mode When this mode is activated the overload capabilities are moved from default value to 330 overload in current and power for maximum 900 ms 0 0 0 CF1049 Start without supervi...

Страница 66: ...3 CF1069 P AC max per phase safe mode Peak shaving for each individual phase 1 if no peak shaving 0 1 1 CF1070 Phase compensation Phase balancing 0 0 1 CF1071 Sierra mode Converter allowed to run in c...

Страница 67: ......