Technical information
sheet
MeteoR2
v3.2EN
Screen
Function
Prog ->
alternating with
8:00 -> 18:00
or (if configured for heating):
HEATING
18.0°C (28.0°C)
• Treatment / Auxiliary / Booster pump : This screen dis-
plays its operating mode (Off/On/Prog + Auto if treat-
ment) alternating with the programmed times if the mode
is PROG or AUTO. An "arrow" symbol is displayed if the
output is active. (The output can be set to ON but not be
active, for example if it is coupled to filtering)
• Heating: This screen displays the current pool water tem-
perature with the set point temperature in brackets. A "heat-
ing" symbol is displayed if the output is active.
In Auto or Prog mode, the scheduled operating times are dis-
played alternately. The end time displayed in Auto mode is
the end time calculated by the appliance depending on the
temperature.
In Auto mode, the calculation is only made
during scheduled operating times.
Socket (Aux2)
On ->
AUXILIARY 2 STATUS (power socket on the side of the
appliance). On or Off. An "arrow" symbol is displayed if the
output is active. (The output can be set to ON but not be ac-
tive, for example if it is coupled to filtering)
07/01/2016
10:10 25.0°C
Displays the current date and time, as well as the pool tem-
perature.
Level Control
Level OK / Safety
stopped
alternating with
Top-up 000:00
LEVEL STATUS: This screen displays the level regulation
status alternating with the top-up totalising counter (000:00
in the example). An "arrow" symbol is displayed if the top-
up output (solenoid) is active.