4.4.7. Cover contact
For pools with an automatic cover, filtering times, and even water treatment times if connected
(Auxiliary 1), must be reduced when the cover is closed. Indeed, in this situation the water is shel-
tered from UVs and most pollutants, so the need is significantly less. Most covers are fitted with a
limit switch that the MeteoR2 can be connected to so that it can adjust its operation.
This contact must be open when the cover is open, and closed when the cover is over the pool.
Use the cable passage at the bottom of the control box and connect the two contact wires directly
to the module (see photo below).
*The cover contact must imperatively be a dry contact with no electric poten-
tial. No other wires (coupling for other devices, etc.) must be connected at the
same location. A connection error can seriously damage the device and will void
the guarantee.
Use a flat tipped screwdriver of a size adapted to the terminal block! (max.
2.5mm)
4.4.8. Offset Zen'iT control box
The Zen'iT control box is connected to the unpluggable terminal block located directly on the mod-
ule. Pass its wire through a supplied cable gland (see photo below)..
Use a flat tipped screwdriver of a size adapted to the terminal block! (max.
2.5mm)