Technical information
sheet
MeteoR2
v3.2EN
5.2.2. Messages
Alternating with the status screen (screen saver) described above, the MeteoR2 gives the user in-
formation to help prevent possible anomalies or to troubleshoot a possible fault. Messages are then
displayed alternating with the device status:
Message
Description
Solution
T° sensor
defect
Water temperature
measurement error
Check the temperature sensor connection.
SUPERVISOR
This message is displayed briefly when entering supervisor mode.
RS485 defect
Internal control box error, communication problem between the
display board and the base (power module).
Current >>
Pump excess intensity detected. The control box must be powered
off to cancel the fault, or OFF Mode must be selected on the Fil-
tering menu. Check that the pump is not defective or jammed.
Current <<
Pump insufficient intensity detected. The control box must be
powered off to cancel the fault, or OFF Mode must be selected
on the Filtering menu. Check that the pump is not running out of
the water.
Pump
calibration
The pump needs to be calibrated. As current monitoring is en-
abled, the MeteoR2 needs to record the pump's nominal current.
To calibrate, press the
. Calibration is automatic (the
pump is activated for a few dozen seconds and is then stopped).
www.c-
cei.fr
26