Technical information
sheet
MeteoR2
v3.2EN
The different possible filtering modes are the following:
• OFF: Filtering is not controlled by the MeteoR2.
• ON: Filtering is in override mode, 24h/24h
• PROG: Filtering will be triggered using the settings for the 3 filtering time slots P1 to P3.
• AUTO: Filtering will be triggered at the start time scheduled for the P1 time slot, for a duration
calculated automatically depending on the water temperature.
Heat regulated filtering calculation method:
– If the pool temperature is higher than 25°C: daily duration = P1 + d
– If the pool temperature is less than 25°C: daily duration = P1 - d/2
where d = |pool T°C - 25°C| and P1 = daily filtering time for the P1 programme
Example of calculated filtering time in AUTO mode;
Pool water
temperature
10°C
15°C
20
25
30
35
Filtering time
in AUTO
mode / P1 = 10h
8h to 18:00
02:30
5h
07:30
10h
15h
20h
Filtering time
in AUTO
mode / P1 = 14h
8h to 22:00
06:30
9h
11:30
14h
19h
24h
Filtering time
in AUTO
mode / P1 = 5h
8h to 13:00
2h
2h
(min.
duration)
02:30
5h
10h
15h
www.c-
cei.fr
31