Technical information
sheet
MeteoR2
v3.2EN
Depending on the system status, the following symbols are shown on the screen;
Symbol
Meaning
Topping up in progress The "top-up solenoid" output is activated.
Output active. (Filtering, Aux1, Aux2 depending on the displayed screen)
Freeze protection active. The temperature is lower than the freeze protection
temperature set on the menu. The pump is activated for 10 minutes per hour if
the temperature is above freezing and permanently if it is below freezing. The
symbol flashes when the pump is running and remains on the rest of the time.
HEATING output active (if auxiliary 1 is configured as HEATING).
Pump disabled. Filtering cannot be activated (Water level too low, IP input,
etc.)
Forced operation. Filtering is forced (Freeze protection, MF input, etc.)
Temperature low. As the current temperature is lower than the minimum tem-
perature (12°C) in AUTO mode, filtering will be activated regularly (freeze
protection monitoring). This is not a fault. The symbol flashes when the pump
is running (30 minutes every 4 hours) and remains on the rest of the time. If
auxiliary 1 is configured as Treatment and if the mode is PROG or AUTO,
then the treatment output is fully stopped.