Technical information
sheet
MeteoR2
v3.2EN
4.4. Connection to electricity
Installation of this project involves a hazard of electric shocks. We strongly
recommend you contract a professional installer. Incorrect installation places
you in danger and may irreversibly damage the product and the equipment
connected to it.
For safety reasons and in compliance with the NF C15-100 standard, the Mete-
oR2 control box must be installed
• either at 3.50 m from the pool edge. This distance takes into account the dis-
tance around obstacles. If the box MeteoR2 is installed behind a wall, this will
then be the distance required to complete the loop and connect to the box.
• or in an in-ground space immediately next to the swimming pool. In this case
the space must be accessible via a hatch which requires a tool to open it.
The MeteoR control box
• must not be directly installed outdoors, it must be sheltered from rain, cleaning or watering spray,
and UVs (sunlight).
• is resistant to light spray but must not be installed in a floodable area.
• must be fitted on a level and stable support and fixed to the wall using the supplied anchors and
screws.
To keep it watertight, it is essential to check that the seal is correctly positioned when closing the
cover, and to tighten the 2 screws on the front face every time the box is accessed.
www.c-
cei.fr
13