58
4) Option Setting
Menu-F4.01: Adjust zero of A-out
Function
Adjust the Zero Output upon Using Analog Out option
Set Range
(0 ~ 24000)
Display Part
Meaning
0000
0.000mA, 0V output
4000
4.000mA, 2V output
4015
4.015mA, 2.007V output
Menu-F4.02: Adjust Span of A-out
Function
Adjust the Maximum Output upon Using Analog Out option
Set Range
(0 ~ 24000)
Display Part
Meaning
10000
10.000 mA, 4.16 V output
20000
20.000 mA, 8.33 V output
24000
24.000 mA, 10.0 V output
Menu-F4.03: Maximum weight of A-out
Function
Maximum Output Weight Value upon Using Analog Out option
Set Range
(0 ~ Max weight)
Display Part
Meaning
1000
2000
Initial value : Max weight
Maximum output at 1000 kg
Maximum output at 2000 kg
Menu-F4.04:
BCD Out Type
Function
BCD Out Type
Set Range
(1~2)
Display Part
Meaning
4-04. 0
Bcd out set to positive logic
4-04. 1
Bcd out set to negative logic