![CAS CI-400 Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/cas/ci-400-series/ci-400-series_owners-manual_2565928022.webp)
23
CAL 3(Zero-set and span calibration)
CAL 3-1
Function: Setting Multi Calibration Step
Range of set value: 1 ~ 5
Used key
Display
Descriptions
Using numeric keys
~
Set the multi step,
= Set,
=Cancel
STEP- 1
Setting multi calibration for step 1
(CAL3-3 and CAL 3-4 are carried out
once)
STEP- 5
Setting multi calibration for step 5
(CAL3-3 and CAL 3-4 are carried out five
times.)
* Function used to compensate the load cell power by calibrating multipoints in a particular sector when
the actual curve od the load cell is not linear like it is in the figure below.
CAL 3-2
Function: Zero Calibration
Used key
Display
Descriptions
= Set,
=Cancel
UnLoAd
Empty the load tray and press the setup key.
1234
The current weight value is displayed.
Confirm 'Stable' and press the setup key.
- - -
Zeroing in progress...
Reference 1. If the zeroing is completed without any error, it will automatically advance to the counterweight weight
setting (CAL 3-3) with no need of further input.
Содержание CI-400 Series
Страница 1: ... 2 ...
Страница 10: ...11 2 Specifications in Appearance 2 1 External Dimension ...
Страница 29: ... 30 4 2 How to Seal the Indicator Sealing ...
Страница 93: ... 94 Connection of Input Output Input AContact Output AContact ...
Страница 104: ...105 Weight Date 8 byte Example weight Byte No 1 2 3 4 5 6 7 8 13 5kg 1 3 5 135kg 1 3 5 135kg 1 3 5 ...
Страница 117: ... 118 MEMO ...
Страница 118: ...119 MEMO ...
Страница 119: ... 120 MEMO ...
Страница 120: ...121 ...