![CAS CI-400 Series Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/cas/ci-400-series/ci-400-series_owners-manual_2565928051.webp)
`
52
Menu-F2.12: COM2 Communication Method
Function
COM2 Communication Method (RS-232C - Output mode)
Set Range
(0 ~ 8)
Display Part
Meaning
2-12. 0
Data is not transmitted
2-12. 1
Transmitted only if the print key is pushed
2-12. 2
Transmitted in both stable/unstable cases (Stream Mode)
2-12. 3
Transmitted only if the weight is stable
2-12. 4
Command Type 1
2-12. 5
Command Type 2
2-12. 6
Command Type 3
2-12. 7
Transmitted only upon completion signal
2-12. 8
Modbus protocol
Reference 1. Refer to Appendix 2, 3 and 4 for command types.
Menu-F2.13: Set RS-422/485 Port
Function
RS-422/485 Port Setting
Set Range
( 0~ 5)
Display Part
Meaning
2-13. 0
Data Bit 8, Stop Bit 1, Parity Bit : None
2-13. 1
Data Bit 7, Stop Bit 1, Parity Bit: Even
2-13. 2
Data Bit 7, Stop Bit 1, Parity Bit: Odd
2-13. 3
Data Bit 7, Stop Bit 2, Parity Bit: Odd
2-13. 4
Data Bit 8, Stop Bit 1, Parity Bit: Even
2-13. 5
Data Bit 8, Stop Bit 1, Parity Bit: Odd
Menu-F2.14: Set RS-422/485 Baud Rate
Function
RS-422/485 Baud Rate Setting
Set Range
(0 ~ 7)
Display Part
Meaning
2-14. 0
1,200 bps
2-14. 1
2,400 bps
2-14. 2
4,800 bps
2-14. 3
9,600 bps
2-14. 4
19,200 bps
2-14. 5
38,400 bps
2-14. 6
57,600 bps
2-14. 7
115,200 bps
Содержание CI-400 Series
Страница 1: ... 2 ...
Страница 10: ...11 2 Specifications in Appearance 2 1 External Dimension ...
Страница 29: ... 30 4 2 How to Seal the Indicator Sealing ...
Страница 93: ... 94 Connection of Input Output Input AContact Output AContact ...
Страница 104: ...105 Weight Date 8 byte Example weight Byte No 1 2 3 4 5 6 7 8 13 5kg 1 3 5 135kg 1 3 5 135kg 1 3 5 ...
Страница 117: ... 118 MEMO ...
Страница 118: ...119 MEMO ...
Страница 119: ... 120 MEMO ...
Страница 120: ...121 ...