70
<Checker mode1> Relay Operation Graph upon Setting (F6.03-4)
1. Required set value input : SP4 > SP3 > SP2 > SP1
2. T3 : Refer to F6.06 (Delay time of judgment-relay output)
T4 : Refer to F6.07 (Operation time of judgment-relay output)
3. Relay Output
Step1 : ON when Near Zero ≤
Weight
< SP1
Step2 : ON when Step1 ≤
Weight
< SP2
Step3 : ON when Step2 ≤
Weight
< SP3
Step4 : ON when Step3 ≤
Weight
< SP4
Above SP4 : ON when SP4 ≤
Weight
Near Zero : F1.23 set value ≥
Weight
≥ 0 range output
4. Status lamp in the front panel is operated in the same manner as the RELAY output.