CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA
Corporation
www.cas-usa.com
13
PERCNT
YES
NO
Yes/No=enable/disable output weight
percentage. Prompt is “PERCENTAGE”
NO
UPCTWT
YES
NO
Yes/No=enable/disable output weight of 1%
percentage. Prompt is “1% REF WT”
NO
COUNT
YES
NO
Yes/No=enable/disable output counts. Prompt is
“QUANTITY”
NO
PCWT
YES
NO
Yes/No=enable/disable output piece weight.
Prompt is “PIECE WT”
NO
BMI YES
NO
Yes/No=enable/disable output height and BMI.
Prompt is “HEIGHT” and “BMI”
NO
ACCUMU
YES
NO
Yes/No=enable/disable output accumulation
times and total. Prompt is “ACC. N” and
“TOTAL”
NO
DATE
YES
NO
Yes/No=enable/disable output date. Prompt is
“DATE”
NO
TIME
YES
NO
Yes/No=enable/disable output time. Prompt is
“TIME”
NO
AD.CODE
YES
NO
Yes/No=enable/disable output ADC's code.
Prompt is “A/D CODE”
NO
BAT.VOL
YES
NO
Yes/No=enable/disable output voltage of
battery. Prompt is “VOLTAGE”
NO
STATUS
YES
NO
Yes/No=enable/disable output scale's status.
Prompt is “STATUS”
NO
B.LINE
NONE
LINE1
How many blank lines after strings output:
NONE=no blank line, LINE1/2/3/4=there're 1,
2,3 or 4 blank lines after strings, used for
paper feed forward 1/2/3/4 lines.
LINE1
LINE2
LINE3
LINE4
COM2 BAUD.RT 1200
9600
selection of com2's baud rate
2400
4800
9600
19200
38400
BYT.FMT
8N1
8N1
selection of com1's byte format:
(1)8N1=8 data bits, No parity check bit, 1 stop
bit; (2)7O1=7 data bits, 1 Odd parity check
bit, 1 stop bit; (3)7E1=7 data bits, 1 Even
parity check bit, 1 stop bit; (4)7O2=7 data
bits, 1 Odd parity check bit, 2 stop bit;
(5)7E2=7 data bits, 1 Even parity check bit, 2
stop bit;
7O1
7E1
7O2
7E2
OUT.MOD
NONE
PRTCMD
Selection com2 output mode: (1) NONE = No
communication; (2) CONT=continuously output;
(3)PRINT=output after PRINT key pressed;
(4)CMD=output after a request command is
CONT
Содержание CI-100A
Страница 1: ......
Страница 2: ...CI 100A Indicator Operation Service Manual CAS USA Corporation www cas usa com ...