15. View or Calibrate Power Voltage
15.1 In this mode, you can examine the voltage of battery, or you can examine the voltage that regulated out
from AC adaptor when no battery is used, you also can calibrate the displayed voltage and set the
voltage value of low battery point.
Note:
(1)The end customer normally no need to calibrate the displayed voltage, these have been done in
factory.
(2) The normal displaying voltage is 4.0V-6.0V
15.2 To go to this working mode, press down
SETUP
until
CONFIG
is shown, using
,
ACC
and
TARE
key to to go to
MISC -
VoL
item, press
TARE
to enter this mode and display battery voltage.
15.3 If the voltage is sure not correct, to calibrate the voltage according to following steps:
15.3.1 Prepare a DC power supply which output voltage can be adjusted from 5V to 8V, output current must
be larger than 0.5A. Power off the indicator, move away AC adaptor, Connect this DC power to battery
connector on main board, adjust voltage to about 5V, power on the indicator, enter battery voltage
display mode by the way of step15.2.
15.3.2 Press down
UNIT
until
CAL.5V
is shown, adjust voltage to 5V, press
TARE
key to confirm 5V
calibration.
15.3.3 When
CAL.6V
is shown, adjust voltage to 6V, press
TARE
key to confirm 6V calibration. When
CV.End
is shown, that means the voltage calibration is completed and then exit to display voltage.
15.4 Press
SETUP
key to return to last menu item, press
ON/OFF
key to prepare to exit this mode
16. View or Set Time
16.1 After entering
SETUP
mode (by press down
SETUP
key more than 3s), using
or
ACC
key to
select
MISC-TIME
item, press
TARE
to display current time.
16.2 Time display Format is: xx:xx:xx(hh-mm-ss) , 24h format
16.3 Press down
UNIT
more than 3s to enter modification time mode. Using
,
ACC
,
UNIT
,
TARE
keys
to modify current time. If time of no operation is more than 5s, it will automatically exit modification mode.
16.4 Press
SETUP
key to return to last menu item, press
ON/OFF
key to prepare to exit this mode
17. View or Set Date
17.1 After entering
SETUP
mode (by press down
SETUP
key more than 3s), using
or
ACC
key to
select
MISC-DATE
item, press
TARE
to display current time.
17.2 Date display Format is: xx.xx.xx(yy-mm-dd)
17.3 Press down
UNIT
more than 3s to enter modification date mode. Using
,
ACC
,
UNIT
,
TARE
keys
to modify current date. If time of no operation is more than 5s, it will automatically exit modification mode.
17.4 Press
SETUP
key to return to last menu item, press
ON/OFF
key to prepare to exit this mode
Содержание CI-100A
Страница 1: ......
Страница 2: ...CI 100A Indicator Operation Service Manual CAS USA Corporation www cas usa com ...