CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA
Corporation
www.cas-usa.com
46
25. Meaning of Some Symbols and Troubleshooting
25.1 Meaning of Symbols:
25.1.1
0
﹉﹉﹉﹉
------ Zero is over the setting range
25.1.2
0
﹍﹍﹍﹍
------ Zero point is below the setting range
25.1.3
Ad
﹉﹉﹉
------ Signal to ADC is over max. range
)
25.1.4
Ad
﹍﹍﹍
------ Signal to ADC is below min. range
25.1.5
﹉﹉﹉﹉
------ Weight is over upper limitation, or display data is over limitation
25.1.6
﹍﹍﹍﹍
------ Weight is below lower limitation
25.1.7
EEP.E1
------ CONFIG or CAL parameters are not correctly set
25.1.8
EEP.E2
------ USER parameter is not correctly set
25.1.9
Lo.bAt
------ Battery voltage is lower than setting.
25.1.10
CAP.- - -
---- Next displaying content is Capacity
25.1.11
CAP.ER
----- Parameters about Capacity is not correct
25.1.12
CAL.Px
----- Calibration on point(x)
25.1.13
CAL.OFF
----- Calibration Seal Switch is on OFF position
25.1.14
CAL.ON
----- Calibration Seal Switch is on ON position
25.1.15
CAL.Er
----- Calibration error, maybe input data or loaded weight is incorrect, unstable, un-linear
25.1.16
CAL.End
----- Calibration is end
25.1.17
OFF
----- Power OFF the indicator
25.1.18
STB.ER
------ Unstable time is lager than setting of USER-HOLD-STB.TIM
25.1.19
AC.xxxx
----- Accumulation times is xxxx
25.1.20
PR.TARE
----- To Preset TARE weight
25.1.21
COMP
---- To go to input COMPARE data mode
25.1.22
HIGH
----- To input HIGH limitation data of Comparison
25.1.23
LOW
----- To input LOW limitation data of Comparison
25.1.24
SPL.Lo
---------- Sample load weight of low point.
25.1.25
SPL.HI
----------- Sample load weight of high point.
25.1.26
SPL.PWT
------- Sample goods weight to calculate piece weight
25.1.27
INP.PCS
--------- input pieces number of weighted goods
25.1.28
UNIT.KG
--------- Unit kg is selected
25.1.29
UNIT.LB
--------- Unit lb is selected
25.1.30
PWT.ER
--------- Piece weight is error, it’s too small (<0.5d).
25.1.31
SPL.PCT
-------- Sample goods weight to calculate
25.1.32
INP.PCT
--------- input percentage of weighted goods
25.1.33
PCT.ER
---------- Unit-Percentage -Weight is too small (<0.5d).
25.1.34
CACU.ER
---------Internal calculation overflows