![CAS CI-100A Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/cas/ci-100a/ci-100a_operation-and-service-manual_2565919028.webp)
CI-100A Indicator Operation & Service Manual
────────────────────────────────────────────────────────
CAS-USA
Corporation
www.cas-usa.com
26
7. Percent Weighing Mode
7.1
In this mode, scale will weigh goods weight on it, calculate and display its percentage after the
unit-percentage-weight of goods is obtained. (NOTE: If
100% display format is set to 100%,
100.0% or 100.00% in CONFIG-FUNC-PERCEN menu item, then, the
unit-percentage-weight
is the weight of 1%, 0.1% or 0.01%
)
7.2
To make percent weighing function be available,
CONFIG-FUNC-PERCEN
menu item shouldn’t be
set to
NONE
.
7.3
To enter percent weighing mode, in normal weighing or counting mode, long press
FUNC
key,
WEIGH/COUNT
will be shown, use
ACC
or
key to select
PERCEN
, then press
TARE
to
confirm go to percent weighing mode. Before new unit-percentage-weight is got, the last
unit-percentage-weight will be used.
7.4
In percent weighing mode, the function of
ZERO, TARE, PRINT, HOLD, PRESET TARE, ACC,
SETUP, ON/OFF
are available.
7.5
To obtain the unit-percentage-weight, there’re two ways : (1) input weight and its percentage, then
scale calculates the unit-percentage-weight, refer operations of step 7.5.1 (2) weigh samples weight
which percentage is known, refer operation of step 7.5.2
7.5.1
Input weight and its percentage from keypad, and calculate unit-percentage-weight: in percent
weighing mode, press
UNIT
key, When
InP.Pct
is shown, press
TARE
key to enter this mode:
7.5.1.1 Before input weight, use
or
ACC
key to select the percentage from 1%, 2%, 5%, 10%, 20%,
50% and 100%, this percentage is corresponding to the weight you will input in following steps
7.5.1.2 When
UNIT.KG
is shown, use
or
ACC
key to select the unit of input weight, use
TARE
key to
confirm and go to next. Press
ZERO
key to exit and back to percent weighing mode.
7.5.1.3 When last stored unit-percentage-weight data is shown, use
,
ACC
,
UNIT
key to input new
unit-percentage-weight, press
HOLD
key more than 3s to input decimal point. Press
TARE
key to
confirm and save it, then go back to percent weighing mode. If the calculated unit-percentage-weight
is less than 0.5d, the indicator will display
Pct.Er
and go back to percent weighing mode.
7.5.2 Obtain
unit-percentage-weight by weighing samples weight which percentage is known: in percent
weighing mode, press
UNIT
key, When
InP.Pct
is shown, use
or
ACC
key to select
SPL.Pct,
press
TARE
key to weigh samples (which percentage is known) weight, calculate piece weight.
Press
ZERO
key to exit and back to percent weighing mode.
7.5.2.1 When
SPL.Lo
is shown, move away any sample on scale and press
TARE
key to confirm, before
scale is stable,
SPL.Lo
will be flashed. After it is stable, it will go to next step. Press
ZERO
key to
exit and back to percent weighing mode.
7.5. 2.2 When
SPL.Hi
is shown, put samples (its percentage is known) onto the scale, Press
TARE
key to
confirm reading weight. Before scale is stable,
SPL.Hi
will be flashed. After it is stable, it will go to
next step. Press
ZERO
key to exit and back to percent weighing mode.
7.5.2.3 After
INP.PCT
being shown, 000000 (position of decimal point is determined by
CONFIG-FUNC-PERCEN
setting) will be displayed, use
,
ACC
,
UNIT
key to input the
Содержание CI-100A
Страница 1: ......
Страница 2: ...CI 100A Indicator Operation Service Manual CAS USA Corporation www cas usa com ...