APPENDIX A — TOUCH PILOT DISPLAY TABLES
The Touch Pilot™ display tables are formatted in alphabetical order based on the point
name description. The line number corresponds to the line number from the top the Touch
Pilot screen. A cross reference to the CCN tables in Appendix C is provided. Please refer
to Appendix C for range and configuration default information.
NOTE: In places where duplicated point name descriptions were used, the headers were
added to the point name description to differentiate them. For example, the description
Compressor Output is used three times for circuits A, B, and C. In this table, the descrip-
tions include Cir A, Cir B, and Cir C.
LEGEND
TOUCH PILOT DESCRIPTION
TOUCH PILOT
POINT NAME
TOUCH PILOT PATH
LINE
READ/
WRITE
CCN TABLE NAME
1 Elec Stage for backup
ehs_back
MAIN MENU\Config\USER
35
RW
Configuration Tables\USER
3 Way Valve Position
Q_3W_VLV
MAIN MENU\Status\QCK_TST2
11
RW
Status Display Tables\QCK_TST2
3 Way Valve Position
Circuit A
fc_vlv_a
MAIN MENU\Status\FREECOOL
14
RO
Status Display Tables\FREECOOL
Circuit B
fc_vlv_b
MAIN MENU\Status\FREECOOL
24
RO
Status Display Tables\FREECOOL
Circuit C
fc_vlv_c
MAIN MENU\Status\FREECOOL
34
RO
Status Display Tables\FREECOOL
3 Way Valve Status
Circuit A
FC_VLV_A
MAIN MENU\Status\FREECOOL
15
RO
Status Display Tables\FREECOOL
Circuit B
FC_VLV_B
MAIN MENU\Status\FREECOOL
25
RO
Status Display Tables\FREECOOL
Circuit C
FC_VLV_C
MAIN MENU\Status\FREECOOL
35
RO
Status Display Tables\FREECOOL
4 way Valve Circuit A
Q_RV_A
MAIN MENU\Status\QCK_TST2
13
RW
Status Display Tables\QCK_TST2
4 way Valve Circuit B
Q_RV_B
MAIN MENU\Status\QCK_TST2
14
RW
Status Display Tables\QCK_TST2
4 Way Refrigerant Valve
Circuit A
RV_A
MAIN MENU\Status\CIRCA_D
24
RO
Status Display Tables\CIRCA_D
Circuit B
RV_B
MAIN MENU\Status\CIRCB_D
24
RO
Status Display Tables\CIRCB_D
Circuit C
RV_C
MAIN MENU\Status\CIRCC_D
23
RO
Status Display Tables\CIRCC_D
Activate
ccnbroad
MAIN MENU\Config\BRODEFS
1
RW
Configuration Tables\BRODEFS\BROCASTS
Active Capacity Override
over_cap
MAIN MENU\Maint\LOADFACT
20
RO
Maintenance Display Tables\LOADFACT
Active Demand Limit Val
DEM_LIM
MAIN MENU\Status\GENUNIT
21
RO
Status Display Tables\GENUNIT
Actual Capacity
cap_t
MAIN MENU\Maint\LOADFACT
8
RO
Maintenance Display Tables\LOADFACT
Actual Capacity Limit
cap_lim
MAIN MENU\Maint\LOADFACT
9
RO
Maintenance Display Tables\LOADFACT
Actual Chiller Current
TOT_CURR
MAIN MENU\Maint\LOADFACT
10
RO
Maintenance Display Tables\LOADFACT
Actual Chiller Current
TOT_CURR
MAIN MENU\Status\GENUNIT
23
RO
Status Display Tables\GENUNIT
Air Cond Enter Valve A
Q_HREA_A
MAIN MENU\Status\QCK_TST2
3
RW
Status Display Tables\QCK_TST2
Air Cond Enter Valve B
Q_HREA_B
MAIN MENU\Status\QCK_TST2
7
RW
Status Display Tables\QCK_TST2
Air Cond Entering Valv A
hr_ea_a
MAIN MENU\Status\RECLAIM
15
RO
Status Display Tables\RECLAIM
Air Cond Entering Valv B
hr_ea_b
MAIN MENU\Status\RECLAIM
25
RO
Status Display Tables\RECLAIM
Air Cond Leaving Valv A
Q_HRLA_A
MAIN MENU\Status\QCK_TST2
4
RW
Status Display Tables\QCK_TST2
Air Cond Leaving Valv B
Q_HRLA_B
MAIN MENU\Status\QCK_TST2
8
RW
Status Display Tables\QCK_TST2
Air Cond Leaving Valve A
hr_la_a
MAIN MENU\Status\RECLAIM
17
RO
Status Display Tables\RECLAIM
Air Cond Leaving Valve B
hr_la_b
MAIN MENU\Status\RECLAIM
27
RO
Status Display Tables\RECLAIM
Air Cooled Reclaim Sel
recl_opt
MAIN MENU\Service\FACTORY
10
RW
Service Configuration Tables\FACTORY
Alarm Equipment Priority
EQP_TYP
MAIN MENU\Config\ALARMDEF
2
RW
Configuration Tables\ALARMDEF\ALARMS01
Alarm Relay Output
Q_ALARM
MAIN MENU\Status\QCK_TST1
48
RW
Status Display Tables\QCK_TST1
Alarm Relay Status
ALARMOUT
MAIN MENU\Status\STATEGEN
28
RO
Status Display Tables\STATEGEN
Alarm Routing Control
ALRM_CNT
MAIN MENU\Config\ALARMDEF
1
RW
Configuration Tables\ALARMDEF\ALARMS01
Alarm State
ALM
MAIN MENU\Status\GENUNIT
13
RO
Status Display Tables\GENUNIT
Alarm System Name
ALRM_NAM
MAIN MENU\Config\ALARMDEF
5
RW
Configuration Tables\ALARMDEF\ALARMS01
Alert Relay Output
Q_ALERT
MAIN MENU\Status\QCK_TST1
49
RW
Status Display Tables\QCK_TST1
Alert Relay Status
ALERT
MAIN MENU\Status\STATEGEN
29
RO
Status Display Tables\STATEGEN
Auto Changeover Active
Mode_12
MAIN MENU\Status\MODES
13
RO
Status Display Tables\MODES
Auto Changeover Select
auto_sel
MAIN MENU\Config\USER
18
RW
Configuration Tables\USER
Auto Start When SM Lost
auto_sm
MAIN MENU\Service\SERVICE1
18
RW
Service Configuration Tables\SERVICE1
AUX Board #1 Part Number
AUX_BRD1
MAIN MENU\Maint\BOARD_PN
4
RO
Maintenance Display Tables\BOARD_PN
AUX Board #2 Part Number
AUX_BRD2
MAIN MENU\Maint\BOARD_PN
5
RO
Maintenance Display Tables\BOARD_PN
AUX Board #3 Part Number
AUX_BRD3
MAIN MENU\Maint\BOARD_PN
6
RO
Maintenance Display Tables\BOARD_PN
AUX Board #4 Part Number
AUX_BRD4
MAIN MENU\Maint\BOARD_PN
7
RO
Maintenance Display Tables\BOARD_PN
AUX Board #5 Part Number
AUX_BRD5
MAIN MENU\Maint\BOARD_PN
8
RO
Maintenance Display Tables\BOARD_PN
Average Ctrl Water Temp
ctrl_avg
MAIN MENU\Maint\LOADFACT
2
RO
Maintenance Display Tables\LOADFACT
RO —
Read Only
RW —
Read/Write