8–3
62-11640
These maintenance schedules are based on the use of approved oils and regular Pre-trip inspections of the unit.
Failure to follow the recommended maintenance schedule may affect the life and reliability of the refrigeration unit.
Unit
1. Check unit mounting bolts
Check
2. Check engine and compressor mounting bolts
Check
3. Check door latches & hinges
4. Check condition of water pump belt
Check
Refrigeration
System
1. Check defrost air switch and calibrate as necessary
2. Check & clean the evaporator coil and all defrost drain hoses
3. Install manifold gauge set and check refrigerant pressure
4. Run APX Control System Pretrip
5. Check calibration of suction pressure transducer
6. Check manual defrost operation
Electrical System
1. Check unit switches and electrical connections
Check
2. Check all ground connections for corrosion & tightness
Check
3. Check stand
−
by plug for signs of wear or damage
Check
4. Check condenser fan amperage
5. Check evaporator fan amperage
6. Check compressor amperage
7. Check heater amperage
c. 5 year or 12,000 Hour Maintenance
Coolant System
1. Drain and flush cooling system
2. Refill with Extended Life Coolant
d. Oil Change Intervals
Oil Type
Oil Change / ESI Filter Change
Petroleum
3000 hours or 2 years (Maximum oil drain interval is 2 years)
Mobil Delvac 1*
4000 hours or 2 years (Maximum oil drain interval is 2 years)
* Mobil Delvac 1 is the only approved synthetic oil
Table 8–1 Maintenance Schedule
System
Operation
Reference Section
Содержание Vector 8500
Страница 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Страница 24: ...1 7 62 11640 62 03958 ...
Страница 25: ...62 11640 1 8 ...
Страница 26: ...1 9 62 11640 ...
Страница 27: ...62 11640 1 10 ...
Страница 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Страница 321: ......
Страница 322: ......