background image

13

DISPLAY MENU

The segments regarding the command status

(

LED “ON”

 = 

command active

) and safety status

(

LED “ON”

 = 

safety device at rest

) light up.

The number of manoeuvres appears on the display. 

This number always remains visible until you 

change the setting. Once 

999999

 has been 

exceeded the lighting up of the decimal point on 

the display equals 1 m the six figure number.

10 sec

PRESS PROG

10 sec

The status of the security devices 

TB

FTCI, FTCS 

and 

CSP 

are always shown on the display.

Memorising the DIP-SWITCH settings and displaying 

the firmware version (“

03.

”)

PRESS

PROG

PRESS

PROG

PRESS

PROG

PRESS PROG

PRESS PROG

10 sec

10 s after the last 

modification you will 

automatically exit the mode 

and the selected values will 

be saved (eg. 4)

10 s after the last 

modification you will 

automatically exit the mode 

and the selected values will 

be saved (eg. 3)

10 sec

10 sec

PRESS PROG

Each time the button is pressed the 
number increases (from 1 to 4).

APL

 = Setting the limited opening space (gate1):

1 = 1/3 of the distance   : 

2 = half the distance 

3 = 2/3 of the distance   : 

4 = the entire distance 

SNS 

= Setting the current sensor.

1 = motor consu 2 amps 
2 = motor consu 3 amps
3 = motor consu 3,5 amps

In the "

test

" mode (activated when the motor has 

stopped) it is possible to check the status of the 

command and safety devices. 

The warning lights will activate once, each time a 

TA-TC-TAL-TD-TB-FTCI-FTCS-CSP

” command is 

received. To return to the normal mode press the button 

again “

test

” will appear, then wait for 10 seconds. 

10 sec

10 sec

PRESS PROG

When the ("

TA-TC-TD-TAL-TB- FTCI-FTCS-CSP

") 

inputs are activated the warning lights will light up.

PRESS PROG

Each time the button is pressed the 
number increases (from 1 to 3).

10 sec

10 s after the last 

modification you will 

automatically exit the mode 

and the selected values will 

be saved (eg. 3)

10 sec

10 sec

10 sec

PRESS PROG

Each time the button is pressed 
the setting changes.

Deceleration settings

1 (Minimum) 2 - 3 - 4 - 5 (Maximum)

PRESS PROG

Each time the button is pressed 
the number increases (from 1 to 3)

.

10 sec

10 s after the last 

modification you will 

automatically exit the mode 

and the selected values will 

be saved (eg. 3)

10 sec

Setting the delay between the gates

1 = minimum gate delay  3 = maximum gate delay

2 = medium gate delay

PRESS PROG

Each time the button is pressed the 
number increases (from 1 to 3)

.

10 s after the last modification 

you will automatically exit the 

mode and the selected values 

will be saved (eg. underground)

PRESS

PROG

PRESS

PROG

PRESS

PROG

Selecting the type of motor

          

BL2124 = operator arm 

        BLA24 = operator arm

HL2524 = underground operator
CUSTOM = third part motor

                            Selecting the type of security contact

  

  0 1 2  3 4 5  6 7  8 9

  TB 

N.C.  N.C.  N.C.  N.C.  N.C.  N.C.  N.C.  N.C.  8.2 KΩ 8.2 KΩ

  FTCS 

N.C.  N.C.  N.C.  N.C.  8.2 KΩ  8.2 KΩ  8.2 KΩ  8.2 KΩ  N.C.  N.C.

  FTCI 

N.C.  N.C.  8.2 KΩ  8.2 KΩ  N.C.  N.C.  8.2 KΩ  8.2 KΩ  N.C.  N.C.

  CSP 

N.C.  8.2 KΩ  N.C.  8.2 KΩ  N.C.  8.2 KΩ  N.C.  8.2 KΩ  N.C.  8.2 KΩ

 For the values from A to F see the paragraph “contact selection” on page 16

10 sec

10 sec

PRESS PROG

Each time the button is 
pressed the setting changes

 

(from 0 ... 9 - A ...F).

10 s after the last 

modification you will 

automatically exit the mode 

and the selected values will 

be saved (eg. 5)

PMT 

= Motor power setting.

from level 1 (2.5A) to level 8 (6.0A)

PRESS

PROG

10 sec

10 sec

10 s after the last modification 

you will automatically exit the 

mode and the selected values 

will be saved (eg. 3)

Parameters only present in CUSTOM motors

SPd

= Speed level during deceleration.

1 = minimum speed  

3 = maximum speed

2 = medium speed

PRESS

PROG

10 sec

10 sec

10 s after the last modification 

you will automatically exit the 

mode and the selected values 

will be saved (eg. 2)

Using the 

PROG

 button you can access the following functions in sequence:

-  memorising the status of the dip-switches;

-  display the status of the command and safety devices;

-  display the number of manoeuvres;

-   access the "

test

" mode;

-  set the limited opening distance;

-  set the current sensor level;

-  selecting the type of motor;

-  selecting the security contact 

(N.C./8.2 kΩ);

-  setting the deceleration time;

-  setting the gate delay time.

Содержание PRG900 Series

Страница 1: ...NE Prima di iniziare l installazione leggere le istruzioni attentamente Schema elettrico impianto tipo Pagina 2 Avvertenze importanti Pagina 3 Collegamento elettrico Pagine 3 4 Procedura di programmaz...

Страница 2: ...2 23 24 LC CH2 5 6 1 2 M1 CMN ELS 12V LS TAL N O FTCS N C P1 J1 B1 CS 1435 DC 0535 35 34 J4 R1 L9 L8 L6 L5 L10 L7 L4 P3 P2 L3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ON DS1 1 2 3 J5 Pos 1 Pos 2 1 2 3 CSP N C...

Страница 3: ...re antischiacciamento anticonvogliamento causa l inversione del moto Attenzione In nessun punto della scheda del programma tore presente la tensione a 230 Vac si ha solamente la bassissima tensione di...

Страница 4: ...he la parte rice vente di tale sicurezze vanno collegate ai carichi controllati CTRL24Vdc Si tenga presente che nel caso sia abilitato il test tra la ricezione del comando e il moto delle ante a passa...

Страница 5: ...O DEL SIMBOLO PAUSE SUL DISPLAY PREMERE PROG ATTENZIONE SE UNA DELLE ANTE DOVESSE MUOVERSI IN CHIUSURA VUOL DIRE CHE LA CONNESSIONE MOTORE NON CORRETTA PERCI RIPREMERE PROG ANNULLANDO LA PROCEDURA DI...

Страница 6: ...rifiche sullo stato dei comandi e sicurezze ed effettuare eventuali manutenzioni Il lampeggiante si attiva una volta ad ogni comando TA TC TD TAL TB FTCI FTCS CSP ricevuto Per tornare al normale funzi...

Страница 7: ...sar necessario alimentare il circuito a parte ed usare il contatto come semplice interruttore possibile azionare a distanza l automazione tramite radiocomando per confi gurare le due funzioni sui can...

Страница 8: ...del sistema quando alimentato a batteria strettamente legata alle condizioni ambientali ed al carico connesso ai morsetti 13 14 fig 1 della centralina che anche in caso di blackout alimentano i circu...

Страница 9: ...llesicurezze verificandochevadanoinallarme LED relativo spento quando un ostacolo si trova in mezzo al loro raggio di azione Se si riscontra un anomalia sostituire la sicurezza guasta oppure ponticell...

Страница 10: ...roduct and all its relative components has been designed and manufactured by Cardin Elettronica who have verified that the product conforms in every aspect to the safety standards in force Any non aut...

Страница 11: ...Dip 10 OFF IfyouwanttoactivatetheFTCI FTCStestboththetransmissionandreceiverparts of the security devices must be connected to the binding post marked CTRL 24 Vdc If the test is active there will be...

Страница 12: ...motor 2 enabled OFF Travel limit motor 2 disabled Dip 14 Not used WHEN THE GATES REACH THE COMPLETELY OPEN POSITION THEY INVERT THE TRAVEL DIRECTION AND AFTER MOVING FOR A FEW CENTIMETRES THEY WILL OP...

Страница 13: ...ion settings 1 Minimum 2 3 4 5 Maximum PRESS PROG Each time the button is pressed the number increases from 1 to 3 10 sec 10 s after the last modification you will automatically exit the mode and the...

Страница 14: ...the transmitter channel buttons memorised will activate their signal buzzer B1 fig 1 3 Press one of the channel buttons on the same transmitter The receivers which do not contain that channel code wil...

Страница 15: ...he door The self sufficiency of the system when it is running on battery power is dependent on the ambient conditions and on the load connected at binding posts 13 14 power is always routed there duri...

Страница 16: ...ng This happens when an N C contact is activated FTCI FTCS CSP during time programming or repositioning Once the passive state of the security devices has been reset the gate door will start moving ag...

Страница 17: ...senseur d effort et la course totale du vantail Une intervention du senseur anti coincement anti entra nement provoque une inversion du sens de marche Attention En aucun point de la carte du programm...

Страница 18: ...ie dispositifs externes contr l s 24 Vdc 1 12 CMN commun pour toutes les entr es sorties 13 CMN commun pour toutes les entr es sorties 14 Sortie dispositifs externes 24 Vdc 1 15 CMN commun pour toutes...

Страница 19: ...ition de fermeture incompl te et est teinte quand le portail est compl tement ferm Mode de fonctionnement des FTCI DIP 8 ON FTCI activ es m me en condition de blocage Si les cellules photo lectriques...

Страница 20: ...TAL TD TB FTCI FTCS CSP re ue Pour r tablir le fonctionnement normal appuyer sur PROG ce qui fera appara tre l indication test et attendre 10 secondes 10 sec L activation des entr es TA TC TD TAL TB...

Страница 21: ...elilfautm moriserlenouveaucode activer une des touches de canal de ce m me metteur Les r cepteurs qui ne contiennent pas le code de cette touche se d sacti veront ce qui est signal par un bip de 5 sec...

Страница 22: ...l L autonomie du syst me en cas d alimentation par batterie est strictement li e aux conditions climatiques et la charge branch e aux bornes 13 14 fig 1 de la centrale qui alimente les circuits qui y...

Страница 23: ...ifiant qu ils passent l tat d alarme relative LED teinte quand un obstacle se trouve dans leur rayon d action En cas d anomalie remplacer le dispositif de s curit d fectueux ou court circuiter la rela...

Страница 24: ...befindet sichdieStromspannungvon230Vac esistalleinnurdiesehrnied rige Sicherheitsspannung vorhanden Gem der Vorschrift ber die elektrische Sicherheit ist es verboten die Anschlussklemmen 7 und 8 direk...

Страница 25: ...en sollen m ssen sowohl der sendende als auch der empfangende Teil dieser Sicherheitsvorrichtungen an die kontrollierten Stromverbraucher CTRL 24 Vdc angeschlossen werden Es ist zu beachten dass bei e...

Страница 26: ...und bleibt solange aktiviert bis der Torfl gel 1 eine Strecke von einigen Zentimetern zur ckgelegt hat Endschalter Motor 1 DIP 12 ON Endschalter Motor 1 eingeschaltet OFF Endschalter Motor 1 ausgesch...

Страница 27: ...licht schaltet sich bei jedem eingehenden Befehl TA TC TD TAL TB FTCI FTCS CSP einmal ein Zur R ckkehr zur normalen Betriebsweise PROG dr cken wonach der Schriftzug test erscheint nun 10 Sekunden abwa...

Страница 28: ...t dass f r die Verwendung des Wachlichtes der Stromkreis separat versorgt werden muss und der Kontakt nur als einfacher Schalter zu verwenden ist Die Automatisierung kann mittels einer Funkfernsteueru...

Страница 29: ...die Anschlussklemmen 13 14 Abb 1 versorgt werden Nur so ist es m glich dass ein ber Funk abgegebener Befehl das Drehtor aktivieren kann Bei Batteriebetrieb h ngt die Betriebsautonomie des Systems sta...

Страница 30: ...bei zu berpr fenist obdieseindenAlarmzustandtreten diesbez glicheLEDerloschen wenn ein Hindernis sich in deren Aktionsradius befindet Wenn eine Anomalie gefundenwird istdiefehlerhafteSicherheitsvorric...

Страница 31: ...mientoprovocalainversi ndelamarcha Atenci n En ning n punto de la tarjeta del programador est presente la tensi n de 230 Vac se dispone s lo de la muy baja tensi n de seguridad Para la conformidad con...

Страница 32: ...chos dispositivos de seguridad deben ser conectadas a las cargas controladas CTRL 24Vdc Considerarquesieltestest habilitado transcurreaproximadamenteunsegundo tras la recepci n de un mandato y el movi...

Страница 33: ...Y PULSAR PROG ATENCI N SI UNA DE LAS HOJAS SE MOVIERA CERR NDOSE SIGNIFICA QUE EL CONEXIONADO DEL MOTOR NO ES CORRECTO POR LO QUE SE DEBER PULSAR DE NUEVO LA TECLA PROG PARA ANULAR EL PROCEDIMIENTO DE...

Страница 34: ...mpo de ralentizaci n 1 m nimo 2 3 4 5 m ximo PULSAR PROG Tras cada pulsaci n de la tecla se incrementar el n mero de 1 a 3 10 seg Despu s de 10 segundos contados a partir de la ltima modificaci n se s...

Страница 35: ...or lo cual significa que para utilizar la luz de zona deber alimentarse el circuito separado y utilizar el contacto como un interruptor simple Es posible accionar a distancia la automatizaci n por med...

Страница 36: ...Laautonom adelsistemacuandoest alimentadoporbater aest estrictamente vinculada a las condiciones ambientales y a la carga conectada en la salida de bornes 13 14 de la centralita que incluso en caso d...

Страница 37: ...D correspondiente apagado cuando un obst culo se encuentra en el medio del radio de acci n de los mismos Si se detectara una anomal a cambiar el dispositivo de seguridad en aver a o puen tear la respe...

Страница 38: ...x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x...

Страница 39: ...39 NOTES...

Страница 40: ...0 50 W Output for a courtesy light with a potential free contact C NO Output for an indicator light 24 Vdc 3W Output for warning lights 24 Vdc 25W continuous or intermittent activation Output for an e...

Отзывы: