Troubleshooting
Fault Code
and Message
Fault
Cause
Correction
Cycle the power the system
Do the factory reset procedure
Fault 116: VCM
Memory
VCM Memory
Settings in the VCM do not
match settings in the Hub.
Upload software to the hub
Cycle the power the system
Do the factory reset procedure
Fault 117:
Boom Profile
Mismatch
Nozzle Memory
The boom profile in memory
doesn't match the attached
hardware.
Upload software to the hub
Cycle the power the system
Verify all valves are functional
Fault 118:
Nozzle Count
Error
Nozzle Count
Error
The number of attached
nozzle valves doesn't match
the value in memory.
Do the factory reset procedure
Cycle the power the system
Do the factory reset procedure
Fault 119:
System Memory
System Memory The hub did not read the
menu settings correctly
from memory.
Contact CapstanAG to repair or
replace the hub.
Fault 120:
Pump Seal
Pump Seal
System pressure dropped
below the minimum for 8
seconds.
Fill the tank and then restart the
pump. To restart the pump: Go
to the main screen CapstanAG
operating screen: Select
System>>On/off icon next to
Pump is system status window
Fault 121:
Control Duty
Cycle Zero
Control Duty
Cycle
The external rate controller
signal is outside off.
Do a check of the rate controller
settings and change as
necessary.
Fault 122: Low
Pressure
Low Pressure
The system is below the
minimum voltage for the
pressure sensor.
Do a check of the pressure
sensor, harnesses, and
connections, repair or replace as
necessary.
Flowmeter calibration
number is incorrect
Do a check of the flowmeter
calibration.
Damaged flowmeter
Repair or replace the flowmeter
as necessary.
Wrong tip size on display
Change the value on the display
Wrong valve size on display Change the value on the display
Boom leak
Do a check of the booms and
repair any damage
Section valve not operating
Do a check of the section valves
and repair/replace as necessary
Plugged strainers
Clean or replace the strainers
Fault 123: Flow
Percentage
Flow
percentage
exceeds the
maximum
value set in the
system menu
Lodged plungers
Clean or replace the plungers
©
2021 Capstan Ag Systems, Inc.
99
PinPoint
™
III ENVELOP
Содержание PinPoint III ENVELOP
Страница 6: ......
Страница 65: ...TM Operation 2021 Capstan Ag Systems Inc 65 PinPoint III ENVELOP...
Страница 66: ...TM Operation Nozzle Spacing 50 cm 2021 Capstan Ag Systems Inc 66 PinPoint III ENVELOP...
Страница 67: ...TM Operation 2021 Capstan Ag Systems Inc 67 PinPoint III ENVELOP...
Страница 69: ...TM Operation 2021 Capstan Ag Systems Inc 69 PinPoint III ENVELOP...
Страница 71: ...TM Operation 2021 Capstan Ag Systems Inc 71 PinPoint III ENVELOP...
Страница 72: ...TM Operation Nozzle Spacing 20 in 2021 Capstan Ag Systems Inc 72 PinPoint III ENVELOP...
Страница 73: ...TM Operation 2021 Capstan Ag Systems Inc 73 PinPoint III ENVELOP...
Страница 75: ...TM Operation 2021 Capstan Ag Systems Inc 75 PinPoint III ENVELOP...
Страница 76: ...TM Operation 2021 Capstan Ag Systems Inc 76 PinPoint III ENVELOP...
Страница 84: ...TM Maintenance 2021 Capstan Ag Systems Inc 84 PinPoint III ENVELOP...
Страница 116: ...TM Troubleshooting 2021 Capstan Ag Systems Inc 116 PinPoint III ENVELOP...
Страница 122: ...TM Schematics System Layout Figure 42 2021 Capstan Ag Systems Inc 122 PinPoint III ENVELOP...
Страница 124: ...TM Schematics 2021 Capstan Ag Systems Inc 124 PinPoint III ENVELOP...
Страница 127: ......