![CapstanAG PinPoint III ENVELOP Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/capstanag/pinpoint-iii-envelop/pinpoint-iii-envelop_operators-manual_2554700103.webp)
TM
Troubleshooting
Problem
Cause
Correction
Low voltage to the rate
controller
Test the voltage and repair as needed
Faulty flowmeter
Repair or replace the flowmeter
Faulty speed sensor reading
Do a check of the radar and replace as needed
Collapsed suction hose
Replace the suction hose
Inlet plugged
Do a check of the inlet and clean as necessary
Incorrect valve calibration
settings
Do a check of the valve calibration settings and
adjust as necessary. Refer to the rate controller
manual
Incorrect system gain
Do a check of the system gain and adjust as
needed
The system run/hold
parameter is too short
Incrementally adjust up the system run/hold
parameter to decrease the instability
Air in the spray boom
Bleed air from the system
Rate instability
Faulty rate controller
Replace the rate controller
Faulty rate controller
Replace the rate controller
Worn or sticky poppet(s)
Do a check of the poppet(s) and replace as
needed
Incorrect system gain setting
Do a check of the system gain setting and adjust
as needed
Pressure
instability
Faulty pressure sensor
Replace the pressure sensor
Plunger is lodged with debris
Clean the nozzle valve
Plunger is worn
Replace the plunger
Single nozzle
valve drips
when shut off
O-ring is pinched or broken
Replace the O-ring
Single nozzle
valve sprays
erratically
Plunger is worn
Replace the plunger
Plunger is lodged with debris
Clean the nozzle valve
Single nozzle
valve will not
shut off
O-ring is pinched or broken
Replace the O-ring
Blown fuse on VCM extension
harness
Replace the fuse on the VCM harness
Faulty VCM
Repair or replace the VCM
Damaged VCM extension
harness
Repair or replace the VCM extension harness
Make sure that the section signal is getting to the
hub.
Section will not
spray
Rate controller is not
activating the section
Repair or replace the rate controller components.
©
2021 Capstan Ag Systems, Inc.
103
PinPoint
™
III ENVELOP
Содержание PinPoint III ENVELOP
Страница 6: ......
Страница 65: ...TM Operation 2021 Capstan Ag Systems Inc 65 PinPoint III ENVELOP...
Страница 66: ...TM Operation Nozzle Spacing 50 cm 2021 Capstan Ag Systems Inc 66 PinPoint III ENVELOP...
Страница 67: ...TM Operation 2021 Capstan Ag Systems Inc 67 PinPoint III ENVELOP...
Страница 69: ...TM Operation 2021 Capstan Ag Systems Inc 69 PinPoint III ENVELOP...
Страница 71: ...TM Operation 2021 Capstan Ag Systems Inc 71 PinPoint III ENVELOP...
Страница 72: ...TM Operation Nozzle Spacing 20 in 2021 Capstan Ag Systems Inc 72 PinPoint III ENVELOP...
Страница 73: ...TM Operation 2021 Capstan Ag Systems Inc 73 PinPoint III ENVELOP...
Страница 75: ...TM Operation 2021 Capstan Ag Systems Inc 75 PinPoint III ENVELOP...
Страница 76: ...TM Operation 2021 Capstan Ag Systems Inc 76 PinPoint III ENVELOP...
Страница 84: ...TM Maintenance 2021 Capstan Ag Systems Inc 84 PinPoint III ENVELOP...
Страница 116: ...TM Troubleshooting 2021 Capstan Ag Systems Inc 116 PinPoint III ENVELOP...
Страница 122: ...TM Schematics System Layout Figure 42 2021 Capstan Ag Systems Inc 122 PinPoint III ENVELOP...
Страница 124: ...TM Schematics 2021 Capstan Ag Systems Inc 124 PinPoint III ENVELOP...
Страница 127: ......