Troubleshooting
Fault Code
and Message
Fault
Cause
Correction
Fault 10:
Internal
Communication
Fault
Processor
to processor
communication
with VCM Port 2
The main hub processor
and VCM 2 port connector
on the hub have stopped
communicating.
If there are any unused VCM
ports on the hub,remove the
VCM harness from the stopped
port and all subsequent ports.
Skipping the stopped port, install
the harnesses to remaining ports
in the same order.
If all of the VCM ports are in use,
contact CapstanAG to repair or
replace the hub.
Fault 11:
Internal
Communication
Fault
Processor
to processor
communication
with VCM Port 3
The main hub processor
and VCM 3 port connector
on the hub have stopped
communicating.
If there are any unused VCM
ports on the hub,remove the
VCM harness from the stopped
port and all subsequent ports.
Skipping the stopped port, install
the harnesses to remaining ports
in the same order.
If all of the VCM ports are in use,
contact CapstanAG to repair or
replace the hub.
Fault 12:
Internal
Communication
Fault
Processor
to processor
communication
with VCM Port 4
The main hub processor
and VCM 4 port connector
on the hub have stopped
communicating.
If there are any unused VCM
ports on the hub,remove the
VCM harness from the stopped
port and all subsequent ports.
Skipping the stopped port, install
the harnesses to remaining ports
in the same order.
If all of the VCM ports are in use,
contact CapstanAG to repair or
replace the hub.
Fault 13:
Internal
Communication
Fault
Processor
to processor
communication
with VCM Port 5
The main hub processor
and VCM 5 port connector
on the hub have stopped
communicating.
If there are any unused VCM
ports on the hub,remove the
VCM harness from the stopped
port and all subsequent ports.
Skipping the stopped port, install
the harnesses to remaining ports
in the same order.
If all of the VCM ports are in use,
contact CapstanAG to repair or
replace the hub.
©
2021 Capstan Ag Systems, Inc.
86
PinPoint
™
III ENVELOP
Содержание PinPoint III ENVELOP
Страница 6: ......
Страница 65: ...TM Operation 2021 Capstan Ag Systems Inc 65 PinPoint III ENVELOP...
Страница 66: ...TM Operation Nozzle Spacing 50 cm 2021 Capstan Ag Systems Inc 66 PinPoint III ENVELOP...
Страница 67: ...TM Operation 2021 Capstan Ag Systems Inc 67 PinPoint III ENVELOP...
Страница 69: ...TM Operation 2021 Capstan Ag Systems Inc 69 PinPoint III ENVELOP...
Страница 71: ...TM Operation 2021 Capstan Ag Systems Inc 71 PinPoint III ENVELOP...
Страница 72: ...TM Operation Nozzle Spacing 20 in 2021 Capstan Ag Systems Inc 72 PinPoint III ENVELOP...
Страница 73: ...TM Operation 2021 Capstan Ag Systems Inc 73 PinPoint III ENVELOP...
Страница 75: ...TM Operation 2021 Capstan Ag Systems Inc 75 PinPoint III ENVELOP...
Страница 76: ...TM Operation 2021 Capstan Ag Systems Inc 76 PinPoint III ENVELOP...
Страница 84: ...TM Maintenance 2021 Capstan Ag Systems Inc 84 PinPoint III ENVELOP...
Страница 116: ...TM Troubleshooting 2021 Capstan Ag Systems Inc 116 PinPoint III ENVELOP...
Страница 122: ...TM Schematics System Layout Figure 42 2021 Capstan Ag Systems Inc 122 PinPoint III ENVELOP...
Страница 124: ...TM Schematics 2021 Capstan Ag Systems Inc 124 PinPoint III ENVELOP...
Страница 127: ......