Maintenance
Chapter 7: Maintenance
Service the System
CAUTION: Before operation or service to the system, read and understand the machine’s
operator manual and the system operator manual. Chemical residue may be present on/in the
OEM equipment. Use the correct personal protective equipment.
Before servicing the system or plumbing components, release the pressure and empty any product
from the system and liquid delivery lines.
Jump Start, Weld On, or Charge the Machine
If jump starting the machine, make sure that you trip the circuit breaker to prevent damage.
If charging the machine’s batteries or welding on the machine, trip the circuit breaker.
Inspect the System
•
Inspect the hoses for cuts, nicks, or abrasions before each use. Immediately replace any
damaged hoses.
•
Make sure that the strainers are clean.
•
Make sure that all hoses and wiring are secure.
•
Do a check for loose hoses, mounting hardware, and other components. Tighten if necessary.
•
Do a check for damaged or missing decals. Replace if necessary.
Clean the System
•
Thoroughly clean the system after each use.
•
Avoid high-pressure spray when cleaning the system components.
Storage of the System
Thoroughly clean the implement and the system before any long storage.
Important: Use of N-Serve requires that the system is flushed with one or two tanks of ammonia
without N-Serve at the end of the season before long storage.
Winterize for Storage
Do not use fertilizer to winterize! The use of fertilizer to winterize will cause internal damage to the
nozzle valves.
Note: Improper winterizing will result in damage to the internal components of the nozzle valves.
Review the manufacturer’s planter manuals for more information on proper winterizing.
Thoroughly clean the system before winter storage. Flush the system with clean water.
Winterize the system with RV antifreeze for winter storage. Proper winterizing of the machine with
a CapstanAG system installed on it is essential. Make sure that the lines are completely full of
antifreeze at 100% strength and that the nozzle valves are purged until 100% antifreeze is seen at all
nozzle valves.
©
2021 Capstan Ag Systems, Inc.
77
PinPoint
™
III ENVELOP
Содержание PinPoint III ENVELOP
Страница 6: ......
Страница 65: ...TM Operation 2021 Capstan Ag Systems Inc 65 PinPoint III ENVELOP...
Страница 66: ...TM Operation Nozzle Spacing 50 cm 2021 Capstan Ag Systems Inc 66 PinPoint III ENVELOP...
Страница 67: ...TM Operation 2021 Capstan Ag Systems Inc 67 PinPoint III ENVELOP...
Страница 69: ...TM Operation 2021 Capstan Ag Systems Inc 69 PinPoint III ENVELOP...
Страница 71: ...TM Operation 2021 Capstan Ag Systems Inc 71 PinPoint III ENVELOP...
Страница 72: ...TM Operation Nozzle Spacing 20 in 2021 Capstan Ag Systems Inc 72 PinPoint III ENVELOP...
Страница 73: ...TM Operation 2021 Capstan Ag Systems Inc 73 PinPoint III ENVELOP...
Страница 75: ...TM Operation 2021 Capstan Ag Systems Inc 75 PinPoint III ENVELOP...
Страница 76: ...TM Operation 2021 Capstan Ag Systems Inc 76 PinPoint III ENVELOP...
Страница 84: ...TM Maintenance 2021 Capstan Ag Systems Inc 84 PinPoint III ENVELOP...
Страница 116: ...TM Troubleshooting 2021 Capstan Ag Systems Inc 116 PinPoint III ENVELOP...
Страница 122: ...TM Schematics System Layout Figure 42 2021 Capstan Ag Systems Inc 122 PinPoint III ENVELOP...
Страница 124: ...TM Schematics 2021 Capstan Ag Systems Inc 124 PinPoint III ENVELOP...
Страница 127: ......