Troubleshooting
Fault Code
and Message
Fault
Cause
Correction
Contact CapstanAG to repair or
replace the hub.
Fault 41:
Internal
Communication
Fault
Compass read
error
Communication
problem with the Inertial
Measurement Unit in the
hub.
Disable the compass and gyro on
the display.
Contact CapstanAG to repair or
replace the hub.
Fault 42:
Internal
Communication
Fault
Gyroscope
initialization
error
Communication
problem with the Inertial
Measurement Unit in the
hub.
Disable the compass and gyro on
the display.
Contact CapstanAG to repair or
replace the hub.
Fault 43:
Internal
Communication
Fault
Gyroscope gyro
read error
Communication
problem with the Inertial
Measurement Unit in the
hub.
Disable the compass and gyro on
the display.
Fault 44: Drop 1
Power Short
Power shorted
to ground on
drop 1
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 45: Drop 2
Power Short
Power shorted
to ground on
drop 2
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 46: Drop 3
Power Short
Power shorted
to ground on
drop 3
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 47: Drop 4
Power Short
Power shorted
to ground on
drop 4
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 48: Drop 5
Power Short
Power shorted
to ground on
drop 5
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 49: Drop 6
Power Short
Power shorted
to ground on
drop 6
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 50: Drop 7
Power Short
Power shorted
to ground on
drop 7
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 51: Drop 8
Power Short
Power shorted
to ground on
drop 8
Damaged harness
Do a check of the harness, repair
or replace as necessary
Fault 52: VCM
drop 1 controller
version error
VCM drop
1 controller
version does
not match the
Hub application
The VCM drop version was
updated with the latest Hub
update and needs to be
boot-loaded.
Do a factory reset or software
reset to trigger VCM drop boot-
load
©
2021 Capstan Ag Systems, Inc.
90
PinPoint
™
III ENVELOP
Содержание PinPoint III ENVELOP
Страница 6: ......
Страница 65: ...TM Operation 2021 Capstan Ag Systems Inc 65 PinPoint III ENVELOP...
Страница 66: ...TM Operation Nozzle Spacing 50 cm 2021 Capstan Ag Systems Inc 66 PinPoint III ENVELOP...
Страница 67: ...TM Operation 2021 Capstan Ag Systems Inc 67 PinPoint III ENVELOP...
Страница 69: ...TM Operation 2021 Capstan Ag Systems Inc 69 PinPoint III ENVELOP...
Страница 71: ...TM Operation 2021 Capstan Ag Systems Inc 71 PinPoint III ENVELOP...
Страница 72: ...TM Operation Nozzle Spacing 20 in 2021 Capstan Ag Systems Inc 72 PinPoint III ENVELOP...
Страница 73: ...TM Operation 2021 Capstan Ag Systems Inc 73 PinPoint III ENVELOP...
Страница 75: ...TM Operation 2021 Capstan Ag Systems Inc 75 PinPoint III ENVELOP...
Страница 76: ...TM Operation 2021 Capstan Ag Systems Inc 76 PinPoint III ENVELOP...
Страница 84: ...TM Maintenance 2021 Capstan Ag Systems Inc 84 PinPoint III ENVELOP...
Страница 116: ...TM Troubleshooting 2021 Capstan Ag Systems Inc 116 PinPoint III ENVELOP...
Страница 122: ...TM Schematics System Layout Figure 42 2021 Capstan Ag Systems Inc 122 PinPoint III ENVELOP...
Страница 124: ...TM Schematics 2021 Capstan Ag Systems Inc 124 PinPoint III ENVELOP...
Страница 127: ......