![CapstanAG PinPoint III ENVELOP Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/capstanag/pinpoint-iii-envelop/pinpoint-iii-envelop_operators-manual_2554700041.webp)
TM
Operation
Boom/Nozzle Settings Menu Descriptions
Nozzle Bounds
Line Title
Line
Number
Description
Zero Speed Spray
1
This feature allows the system to apply product when the machine is not moving. Select
On to allow the system to spray when the machine is not moving. Select Off to make sure
that the system will not spray when the machine is stopped.
PWM Minimum %
2
This is the minimum pulse duty cycle for the nozzle valves. This value must not be lower
than the Nozzle Pulse Frequency.
PWM Maximum %
3
This is the limit of the maximum nozzle duty cycle.
Nozzle Pulse Frequency
4
CapstanAG systems run at 10 pulses per second pulse frequency. CapstanAG does not
recommend pulse frequencies slower than 10Hz in sprayer applications.
Low Press Shutoff
5
When enabled, this setting causes the solenoid valves to shut off, like diaphragm drip
checks at this value. When the low pressure shutoff value is 8 PSI, a message will show
when the pressure goes below 8 PSI. At this point, nozzle valves will close. Nozzle valves
will open, and the message will clear when the pressure increases to at least 12 PSI.
Valve Type
Solenoid valve type that the system uses for flow detection.
7W 7-watt Coil
12W 12-watt Coil
6
12WH 15-series valve with 12-watt coil and a heavy spring plunger
©
2021 Capstan Ag Systems, Inc.
41
PinPoint
™
III ENVELOP
Содержание PinPoint III ENVELOP
Страница 6: ......
Страница 65: ...TM Operation 2021 Capstan Ag Systems Inc 65 PinPoint III ENVELOP...
Страница 66: ...TM Operation Nozzle Spacing 50 cm 2021 Capstan Ag Systems Inc 66 PinPoint III ENVELOP...
Страница 67: ...TM Operation 2021 Capstan Ag Systems Inc 67 PinPoint III ENVELOP...
Страница 69: ...TM Operation 2021 Capstan Ag Systems Inc 69 PinPoint III ENVELOP...
Страница 71: ...TM Operation 2021 Capstan Ag Systems Inc 71 PinPoint III ENVELOP...
Страница 72: ...TM Operation Nozzle Spacing 20 in 2021 Capstan Ag Systems Inc 72 PinPoint III ENVELOP...
Страница 73: ...TM Operation 2021 Capstan Ag Systems Inc 73 PinPoint III ENVELOP...
Страница 75: ...TM Operation 2021 Capstan Ag Systems Inc 75 PinPoint III ENVELOP...
Страница 76: ...TM Operation 2021 Capstan Ag Systems Inc 76 PinPoint III ENVELOP...
Страница 84: ...TM Maintenance 2021 Capstan Ag Systems Inc 84 PinPoint III ENVELOP...
Страница 116: ...TM Troubleshooting 2021 Capstan Ag Systems Inc 116 PinPoint III ENVELOP...
Страница 122: ...TM Schematics System Layout Figure 42 2021 Capstan Ag Systems Inc 122 PinPoint III ENVELOP...
Страница 124: ...TM Schematics 2021 Capstan Ag Systems Inc 124 PinPoint III ENVELOP...
Страница 127: ......