a) CO, HC, CO2 adjustment procedure:
Adjusting calibration gas concentrations:
HC must be entered in propane equivalent.
Remember that the cylinder containing the gas required for analyser adjustment contains the
following concentrations:
CO: 2,00 % vol.
CO
2
: 13,0 % vol.
HC: 1600 ppm vol. propane
Balance N
2
The operator must enter the values of the CO, CO2 and HC gas concentrations. To go to the next
step, OK or ENTER must be pressed.
Launching the adjustement procedure:
The operator is guided throughout the procedure by messages indicating the various steps that
the machine carries out during an adjustment procedure.
b) O2 initialization:
New O2 sensor:
This tab is used for installing a new O2 sensor. It is necessary to follow the procedure, which
requires changing the O2 sensor first, then pressing OK. Once this step is completed, the machine
initializes the sensor for 1 minute. This consists in recovering the new sensor reference voltage.
O2 0% adjustment:
To adjust O2 sensor to 0%.
c) NOx initialization:
Same as O2 sensor initialization.