23/04/2019
Rev 3
34
II.6.
Messages :
Message displayed
Call
Maintenance
Do it yourself
Leak present
YES
Data invalid
YES
HC out of bounds
YES
CO out of bounds
YES
CO2 out of bounds
YES
O2 out of bounds
YES
NOx out of bounds
-
-
Lowflow detected
YES
HC residue in gas inlet
YES
Error com.
YES
Adjustment necessary
YES
Change O2 sensor
YES
Condensation: wait
YES
Heating problem
YES
II.6.1.Leak present
Repeat the test, disconnecting the probe from the device and plugging the gas entry port on the
separator. If the problem disappears, the leak is in the probe tubing.
Otherwise, it affects the machine. Check the filter connections. Check that the separator is
correctly installed and adequately tightened.
Test the various parts of the pneumatic circuit with leak tests, moving the plug progressively
upstream, up to the pumps.
Open the machine and perform a visual check of the pneumatic circuit.
Replace the leaking portion of the pneumatic circuit.
II.6.2.Data invalid
Adjustment necessary.
II.6.3.HC out of bounds
Out of range.
Содержание EOBD
Страница 2: ......
Страница 7: ...23 04 2019 Rev 3 4 I 2 Overview I 2 1 The Station ...
Страница 10: ...23 04 2019 Rev 3 7 I 2 4 Smoke meter Exhaust probe ...
Страница 13: ...23 04 2019 Rev 3 10 CAP4XXX RPM via the EOBD Allows to measure the RPM from the vehicle embedded computer ...
Страница 23: ...23 04 2019 Rev 3 20 II 1 3 Gas flow circuit diagram ...
Страница 63: ...23 04 2019 Rev 3 60 ...