23/04/2019
Rev 3
41
III.3.
TECHNICAL FEATURES
Power supply 115-230V / 1.5A; 47Hz à 63Hz.
Preheating duration: from 3 to 6 min depending on ambient temperature.
Zero adjustment and calibration before use: automatic.
Control of adjustment: automatic by electrical filter at around 50%.
Ambient temperature range for operation: +5 to +40°C.
Humidity: 30% to 90%.
Storage temperature: -32°C to +55°C.
Measurement range of the measured value:
Opacity: 0.00 to 9.99 m
-1
. 0.0 to 99.9%
Resolution 0.01 m
-1
or 0.1%
Maximum relative error:
Measurement range of influencing factors (which allow correction of the
opacity value):
Temperature of the gas being measured: 0-256 C (resolution 1°C)
Physical response time 10% to 90%: less than 0.2 sec. for gas at 75L/min.