II.6.12.Change O
2
sensor
During a zero operation, the system associates the oxygen concentration in air (20.9%) with the
corresponding potential at the terminals of the oxygen sensor. This potential is usually in the
range [6mV - 13mV]. If the potential is not in this range, the message “Change O2 sensor”
appears. This means that the oxygen sensor is defective or incorrectly connected.
Please contact your manufacturer or supplier for O
2
sensor replacement.
II.6.13.Condensation: wait
This message may appear during the start-up phase. In this case, just wait for the machine to be
warmed up and ready to carry out measurements.
If on the other hand this message appears in the course of a measurement and persists, it is
necessary to carry out a check of the following points:
Check that the separator is correctly connected.
Check the flow at the condensate exhaust connector.
Check the internal parameters in the maintenance menu.
Perform a leak test.
Depending on the results obtained, notify Maintenance, which will
undertake the replacement of the defective part.
II.6.14.Heating problem
If the estimated warm-up time of the machine (elapsed time between the time the machine is
turned on and the time when measurements are possible) is exceeding 15 minutes, this message
will appear.
If the temperature is below 5°C, it is necessary to move the equipment to a hotter place and
restart it.
II.6.15.Other :
(1)
RPM out of range
This is shown on screen by a “----“ display.
If this message appears, it means that the measurement of operating speed is over 9999 rpm.
Check that the correct sensor has been chosen in the Operating Speed menu and the information
concerning the engine to be tested is correct and has been completed.
(2)
TMP. Out of range
Содержание EOBD
Страница 2: ......
Страница 7: ...23 04 2019 Rev 3 4 I 2 Overview I 2 1 The Station ...
Страница 10: ...23 04 2019 Rev 3 7 I 2 4 Smoke meter Exhaust probe ...
Страница 13: ...23 04 2019 Rev 3 10 CAP4XXX RPM via the EOBD Allows to measure the RPM from the vehicle embedded computer ...
Страница 23: ...23 04 2019 Rev 3 20 II 1 3 Gas flow circuit diagram ...
Страница 63: ...23 04 2019 Rev 3 60 ...