23/04/2019
Rev 3
24
Replace the activated charcoal filter. (FCC),
Check with a calibration gas that the error is less than the maximum allowed
error.
1) Put into measuring mode.
2) Disconnect the sampling probe from the separator.
3) Connect the cylinder of calibration gas in its place. If the cylinder
contains propane HC, select display of C6 HC, even though display is
usually in C3 (hexane). Otherwise, use the PEF value to convert if the
HC are around 2000 ppm vol. propane.
4) Write down or print the stabilized measured values.
If the error is too high compared to current regulatory requirements,
adjustment is necessary.
If regulation requires regular adjustment using a calibration gas, this
operation must be performed prior to error testing.
II.4.2.3.Probe maintenance
The small holes at the end of the probe must never be connected. If condensation is generated or
if too much residue is produced, remove the probe from the tube and blow compressed air in the
opposite direction to that of suction. Perform the same operation with the sampling hose.
II.4.2.4.Separator maintenance
The separator includes a filter.
Replace the filter it has turned to grey.
Filter replacement is carried out in the following manner:
- turn the pumps off
- Unscrew the condensation residue collector located at the back of the machine. (FD).
The absence of one of the components inside of the separator or incorrect reassembly of the
assembly will contaminate the measuring device and the measurements will be prematurely
invalidated due to the resulting errors. This condition of the analyzer will require an overhaul that
cannot be provided in the frame of warranty.
Perform a leak test.
Содержание EOBD
Страница 2: ......
Страница 7: ...23 04 2019 Rev 3 4 I 2 Overview I 2 1 The Station ...
Страница 10: ...23 04 2019 Rev 3 7 I 2 4 Smoke meter Exhaust probe ...
Страница 13: ...23 04 2019 Rev 3 10 CAP4XXX RPM via the EOBD Allows to measure the RPM from the vehicle embedded computer ...
Страница 23: ...23 04 2019 Rev 3 20 II 1 3 Gas flow circuit diagram ...
Страница 63: ...23 04 2019 Rev 3 60 ...