CHAPTER 14 TROUBLESHOOTING
14-64
COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Cause
Counter
DC controller
PCB
Action
End.
Replace the counter.
Replace the DC
controller PCB.
Step
1
2
Yes/No
YES
NO
YES
Check
Check the wring and the
connectors. Then, turn off and on
the power. Is the problem
corrected?
Turn off the main power switch,
and disconnect the connector (J9)
of the counter. Is the resistance on
the counter side about 480
Ω
?
8
E030 (The toner copy counter fails to operate.)
9
E032 (The copy data controller counter has a fault.)
Cause
Connector
Communication
cable
Copy data
controller
Image processor
PCB
Action
Correct the connection.
Replace the
communication cable.
Replace the copy data
controller.
Replace the image
processor PCB.
Step
1
2
3
Yes/No
NO
NO
YES
NO
Check
Are the connectors of the
communication cable between the
copy data controller and the
machine connected correctly?
Does the communication cable
from the copy data controller to the
machine have an open circuit?
Replace the copy data controller. Is
the problem corrected?
Содержание imageRunner 330
Страница 434: ...COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON 14 35 ...
Страница 648: ...APPENDIX A 6 COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 656: ...A 14 COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 660: ...0996S9 9 1 PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 70 reprocessed paper ...