COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
14-225
CHAPTER 14 TROUBLESHOOTING
A. Copier
Code
E001
E000
E002
E003
Detail
0001
0002
0003
Cause
The fixing temperature does not increase.
The main thermistor (TH1) has poor
contact or an open circuit.
The fixing heater has an open circuit.
The thermal switch has an open circuit.
The DC controller PCB has a fault.
The image processor PCB has fault.
The fixing temperature has increased
abnormally.
The main thermistor (TH1) has a short
circuit.
The fixing heater drive circuit has a fault.
The DC controller PCB has a fault.
The image processor PCB has a fault.
The sub thermistor has detected
overheating.
The main thermistor (TH) has a short
circuit.
The fixing heater drive circuit has a fault.
The DC controller PCB has a fault.
The image processor PCB has a fault.
The sub thermistor has an open circuit.
The sub thermistor has an open circuit.
The SSR has a fault.
The DC controller PCB has a fault.
The image processor PCB has a fault.
The fixing temperature does not reach a
specific value.
The thermistor (TH1, TH2) is not
mounted properly, has poor contact, or
has an open circuit.
The fixing heater has an open circuit
or has a crack.
The fixing heater drive circuit has a fault.
The DC controller PCB has a fault.
The image processor PCB has a fault.
The fixing temperature has dropped
abnormally.
The thermistor (TH1, TH2) is not
mounted properly, has poor contact, or
has an open circuit.
The fixing heater has an open circuit
or has a crack.
The fixing heater drive circuit has a fault.
The DC controller PCB has a fault.
The image processor PCB has a fault.
Description
The main thermistor reading
does not reach 55°C 45 sec
after the main power switch has
been turned on.
The output of the main
thermistor has exceeded 220°C.
The output of the sub
thermistor has exceeded 235°C.
The output of the main thermistor
satisfies the following:
31 sec or more between
40°C and 75°C.
23 sec or more between
75°C and 100°C
19 sec or more between
100°C and 120°C
19 sec or more between
120°C and 140°C
19 sec or more between
140°C and 160°C.
15 sec or more between
160°C and 170°C.
The thermistor (TH1,
TH2) has detected 100°C or
less after wait-up.
Содержание imageRunner 330
Страница 434: ...COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON 14 35 ...
Страница 648: ...APPENDIX A 6 COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 656: ...A 14 COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 660: ...0996S9 9 1 PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 70 reprocessed paper ...