COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 400/330 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
14-227
CHAPTER 14 TROUBLESHOOTING
No code indication.
Control panel keys
locked.
E100
E110
E191
Cause
The high-voltage (primary charging,
transfer charging, development) output
has a fault.
The composite power supply PCB has
a fault.
The DC controller PCB has a fault.
The wiring has a fault (short circuit,
open circuit).
BD error has occurred.
The laser unit has a fault.
The BD PCB has a fault.
The BD PCB has a fault.
The laser driver PCB has a fault.
The laser scanner motor does not generate
clock pulses.
The laser scanner motor (M3) has a
fault.
The laser scanner driver PCB has a
fault.
The DC controller PCB has a fault.
The serial communication between the
DC controller PCB and the composite
power supply PCB has a fault.
The scanner home position cannot be
detected.
The scanner home position sensor
(PS1) has a fault.
The scanner motor (M3) has a fault.
The DC controller PCB has a fault.
The scanning lamp turns on abnormally.
The scanning lamp has a fault.
The intensity sensor has a fault.
The CCD PCB has a fault.
The composite power supply PCB has
a fault.
The DC controller PCB has a fault.
The communication on the image
processor PCB has a fault.
The communication between the DC-
CPU and the IP-CPU has an error.
Description
The difference between the
output prescribed by the
high-voltage control signal
and the high-voltage output
actually generated is more
than a specific value.
Either the primary charging
roller, transfer charging
roller, or developing bias
has an output error.
The BD signal is not
generated during image
formation (2nd sheet pick-
up and later).
The BD signal cycle has
deviated.
The BD signal is not
generated within 2 sec after
the laser has turned on (at
time of 1st sheet pick-up).
The laser scanner motor
does not reach a specific
speed after the laser scanner
motor drive signal has been
generated.
The laser scanner motor
deviates from a specific
speed after it has reached it.
The communication data is
not updated for 8 sec or more.
The check sum of the
communication data varies
three times continuously.
The scanner does not reach
the home position after it
has started to operate.
The lamp intensity does not
exceed a specific value
within a specific time after
scanning operation starts
(following lamp activation).
The lamp remains off for 10
sec when it should remain on.
A communication error is
detected between the DC-CPU
and the IP-CPU on the image
processor CPB.
E202
E220
E240
Detail
0001
0002
Code
E064
Содержание imageRunner 330
Страница 434: ...COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON 14 35 ...
Страница 648: ...APPENDIX A 6 COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 656: ...A 14 COPYRIGHT 1999 CANON INC CANON imageRUNNER 400 330 REV 0 JAN 1999 PRINTED IN JAPAN IMPRIME AU JAPON ...
Страница 660: ...0996S9 9 1 PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 70 reprocessed paper ...