ISO Speed/Gain
76
ISO Speed/Gain
Depending on the shooting conditions, you may want to adjust the brightness of the image. You can do so by
changing the ISO speed or gain value to adjust the sensitivity of the sensor. You can also perform this function
remotely using Browser Remote on a connected network device (
A
The minimum sensitivity needed to obtain the recommended dynamic range depends on the camera model and
other settings.
Available ISO speed and gain settings
* Sensitivity settings that are outside the recommended range but can still be used by setting
[ISO/GAIN]
>
[OPTIONS]
>
[Extended Range] to [On].
**Available only when the extended range is not activated.
Model and other conditions
[Gamma] setting in the custom picture file (
A
[Canon Log] or [Wide DR]
[Canon Log 2] or [Canon Log 3]
Z[
ISO 400 / 6 dB
ISO 800 / 12 dB
]
condition set
햲
:
Slow & fast motion recording is not activated.
ISO 800 / 6 dB
ISO 1600 / 12 dB
]
condition set
햳
:
Slow & fast motion recording is activated ([On] or [On (crop)]).
ISO 1600 / 12 dB
ISO 3200 / 24 dB
Z[
ISO/Gain increment
Normal range
Extended range*
ISO speed
[1 stop]
(1-stop increments)
160**, 200, 400, 800, 1600, 3200, 6400, 12800, 25600
100, 51200, 102400
[1/3 stop]
(1/3-stop increments)
160, 200, 250, 320, 400, 500, 640, 800, 1000, 1250, 1600,
2000, 2500, 3200, 4000, 5000, 6400, 8000, 10000, 12800,
16000, 20000, 25600
100, 125, 32000, 40000, 51200,
64000, 80000, 102400
Gain
[Normal]
(3-dB increments)
–2 dB**, 0 dB to 42 dB
–6 dB, –3 dB, 45 dB to 54 dB
[Fine]
(0.5-dB increments)
2 dB to 42 dB
42.5 dB to 54 dB
]
ISO/Gain increment
Normal range
Extended range*
ISO speed
[1 stop]
(1-stop increments)
Condition set
햲
:
320**, 400, 800, 1600, 3200, 6400, 12800, 25600
Condition set
햳
:
640**, 800, 1600, 3200, 6400, 12800, 25600
Condition set
햲
:
200, 51200, 102400
Condition set
햳
:
400, 51200, 102400
[1/3 stop]
(1/3-stop increments)
Condition set
햲
:
320, 400, 500, 640, 800, 1000, 1250, 1600, 2000, 2500,
3200, 4000, 5000, 6400, 8000, 10000, 12800, 16000, 20000,
25600
Condition set
햳
:
640**, 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000,
5000, 6400, 8000, 10000, 12800, 16000, 20000, 25600
Condition set
햲
:
200, 250, 32000, 40000, 51200,
64000, 80000, 102400
Condition set
햳
:
400, 500, 32000, 40000, 51200,
64000, 80000, 102400
Gain
[Normal]
(3-dB increments)
Condition set
햲
: –2 dB**, 0 dB to 36 dB
Condition set
햳
: 4 dB** to 36 dB
Condition set
햲
:
–6 dB, –3 dB, 39 dB to 48 dB
Condition set
햳
:
0 dB, 3 dB, 39 dB to 48 dB
[Fine]
(0.5-dB increments)
Condition set
햲
: –2 dB to 36 dB
Condition set
햳
: 4 dB to 36 dB
Condition set
햲
,
햳
:
36.5 dB to 48 dB