NL240 Wireless Network Link Interface
•
On the NL240 tab:
o
Set
Bridge Mode
to
disable
.
•
On the RS-232 tab:
o
Set
Configuration
to
TCP Serial Server
.
o
Set
Baud Rate
to baud rate of attached device.
o
Make note of the
Service Port
. (The default RS-232
Service Port
is
6784
. Typically, it is not necessary to change this entry from its
default.)
CS I/O Serial Server
•
Connect to the NL240 in
DevConfig
(see Section
7
,
Configuring the
NL240
(p. 13)
).
•
On the NL240 tab:
o
Set
Bridge Mode
to
disable
.
•
On the CS I/O tab:
o
Set
Configuration
to
TCP Serial Server
.
o
Set
SDC address
. (Note that if multiple peripherals are connected to
a datalogger’s CS I/O port, each must have a unique SDC address.)
o
Make note of the
Service Port
. (The default CS I/O
Service Port
is
6783
. Typically, it is not necessary to change this entry from its
default.)
8.2.3.3 LoggerNet Setup
The next step is to run
LoggerNet
and configure it to connect to the datalogger
via the Wi-Fi port. (See example in FIGURE
8-3
below.)
•
In the
LoggerNet Setup
screen, press
Add Root
and choose
IPPort
. Input
the NL240’s IP address and port number. The IP address and port number
are input on the same line separated by a colon.
•
Add a PakBus® Port.
•
Add the datalogger and input the PakBus® address of the datalogger.
•
Press
Apply
to save the changes.
•
You can verify your settings are correct by selecting the datalogger in the
Network Map, selecting the Clock tab, and pressing
Check Clocks
. If
your settings are correct, you should see the current clock of your server
and datalogger.
23
Содержание NL240
Страница 2: ......
Страница 6: ......
Страница 10: ...Table of Contents iv...
Страница 44: ...NL240 Wireless Network Link Interface 34...
Страница 50: ...Appendix B Cables Pinouts LED Function and Jumper B 4...
Страница 68: ...Appendix C NL240 Settings C 18...
Страница 72: ...Appendix E Radio Frequency Emission E 2...
Страница 73: ......