![Campbell CR800 Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/campbell/cr800-series/cr800-series_operators-manual_489099064.webp)
Section 5. Overview
64
5.1.1.4.5 Ethernet Port
Read More
See the section
TCP/IP — Details
(p. 428).
•
Ethernet capability requires a peripheral Ethernet interface device, as
listed in
Network Links — List
(p. 570).
5.1.1.5 Grounding — Overview
Related Topics:
•
Grounding — Overview
(p. 64)
•
Grounding — Details
(p. 96)
Proper grounding lends stability and protection to a data acquisition system. It is
the easiest and least expensive insurance against data loss — and often the most
neglected. The following terminals are provided for connection of sensor and
CR800 datalogger grounds:
•
Signal ground reference for single-ended analog inputs, pulse
inputs, excitation returns, and as a ground for sensor shield wires. Signal
returns for pulse inputs should use
terminals located next to the pulse
input terminal. Current loop sensors, however, should be grounded to
power ground.
•
G
Power ground return for
5V
,
SW12
,
12V
terminals, current loop
sensors, and
C
configured for control. Use of
G
grounds for these
outputs minimizes potentially large current flow through the analog-
voltage-measurement section of the wiring panel, which can cause
single-ended voltage measurement errors.
•
Earth ground lug connection point for a heavy-gage earth-ground
wire. A good earth connection is necessary to secure the ground potential
of the CR800 and shunt transients away from electronics. Minimum 14
AWG wire is recommended.
5.2
Measurements — Overview
Related Topics:
•
Sensors — Quickstart
(p. 35)
•
Measurements — Overview
(p. 64)
•
Measurements — Details
(p. 311)
•
Sensors — Lists
(p. 567)
Most electronic sensors, whether or not they are supplied by Campbell Scientific,
can be connected directly to the CR800.
Manuals that discuss alternative input routes, such as external multiplexers,
peripheral measurement devices, or a wireless sensor network, can be found at
www.campbellsci.com/manuals
.
Содержание CR800 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 34: ......
Страница 54: ......
Страница 92: ......
Страница 190: ...Section 7 Installation 190 FIGURE 40 Running Average Frequency Response FIGURE 41 Running Average Signal Attenuation ...
Страница 310: ......
Страница 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Страница 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Страница 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Страница 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Страница 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Страница 456: ......
Страница 462: ......
Страница 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Страница 524: ......
Страница 526: ......
Страница 556: ......
Страница 558: ......
Страница 560: ......
Страница 597: ......