Section 8. Operation
377
o
Falling edge — transition from >3.5 Vdc to <1.5 Vdc.
•
Edge-timing resolution is approximately 540 ns.
8.1.3.6 Edge Counting
Edge counts can be measured on
C
terminals.
o
C Terminals
•
Maximum input frequency 400 kHz
•
CRBasic instruction:
TimerIO()
•
Rising or falling edges of a square-wave signal are detected:
o
Rising edge — transition from <1.5 Vdc to >3.5 Vdc.
o
Falling edge — transition from >3.5 Vdc to <1.5 Vdc.
8.1.3.7 Timer Input on I/O NAN Conditions
•
NAN
is the result of a
TimerIO()
measurement if one of the following
occurs:
o
Timeout expires
o
The signal frequency is too fast (> 3 KHz). When a
C
terminal
experiences a too fast frequency, the CR800 operating system
disables the interrupt that is capturing the precise time until the next
scan is serviced. This is done so that the CR800 processor does not
get occupied by excessive interrupts. A small RC filter retrofitted
to the sensor switch should fix the problem.
8.1.3.8 Pulse Measurement Tips
Basic connection of pulse-output sensors is illustrated in table
Switch Closures
and Open Collectors
(p. 378,
The
PulseCount()
instruction, whether measuring pulse inputs on
P
or
C
terminals, uses dedicated 24-bit counters to accumulate all counts over the
programmed scan interval. The resolution of pulse counters is one count or 1 Hz.
Counters are read at the beginning of each scan and then cleared. Counters will
overflow if accumulated counts exceed 16,777,216, resulting in erroneous
measurements.
•
Counts are the preferred
PulseCount()
output option when measuring
the number of tips from a tipping-bucket rain gage or the number of
times a door opens. Many pulse-output sensors, such as anemometers
Содержание CR800 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 34: ......
Страница 54: ......
Страница 92: ......
Страница 190: ...Section 7 Installation 190 FIGURE 40 Running Average Frequency Response FIGURE 41 Running Average Signal Attenuation ...
Страница 310: ......
Страница 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Страница 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Страница 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Страница 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Страница 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Страница 456: ......
Страница 462: ......
Страница 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Страница 524: ......
Страница 526: ......
Страница 556: ......
Страница 558: ......
Страница 560: ......
Страница 597: ......