Section 8. Operation
416
Operating systems can also be sent using the program
Send
feature in
datalogger
support software
(p. 86).
A full reset does not occur in this case. Beginning with
CR800 operating system v.16, settings and fields in the
Status
table are preserved
when sending a subsequent operating system by this method; data tables are
erased. Rely on this feature only with an abundance of caution when sending an
OS to CR800s in remote, expensive to get to, or difficult-to-access locations.
8.8.3.2 Program Send Reset
Final-storage
(p. 499)
data are erased when user programs are uploaded, unless
preserve / erase data options are used. Preserve / erase data options are presented
when sending programs using
File Control
Send
(p. 498)
command and
CRBasic
Editor
Compile, Save and Send
(p. 494).
See
Preserving Data at Program Send
(p.
for a more-detailed discussion of preserve / erase data at program send.
8.8.3.3 Manual Data-Table Reset
Data-table memory is selectively reset from
•
Support software
Station Status
(p. 516)
command
•
CR1000KD Keyboard/Display: Data | Reset Data Tables
8.8.3.4 Formatting Drives
CPU:, USR:, andUSB: drives can be formatted individually. Formatting a drive
erases all files on that drive. If the currently running user program is found on
the drive to be formatted, the program will cease running and any SRAM data
associated with the program are erased. Drive formatting is performed through
datalogger support software
Format
(p. 498)
command.
8.8.4 File Management in CR800 Memory
As summarized in table
File Control Functions
(p. 416),
files in CR800 memory
(program, data, CAL, image) can be managed or controlled with
datalogger
support software
(p. 86),
the CR1000KD keyboard/display (see
Keyboard Display
— Details
(p. 443))
,
Web API
or
CoraScript
(p. 493).
Use of
CoraScript
is
described in the
LoggerNet
software manual, which is available at
www.campbellsci.com
. More information on file attributes that enhance
datalogger security, see the
Security — Overview
section.
Содержание CR800 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 34: ......
Страница 54: ......
Страница 92: ......
Страница 190: ...Section 7 Installation 190 FIGURE 40 Running Average Frequency Response FIGURE 41 Running Average Signal Attenuation ...
Страница 310: ......
Страница 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Страница 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Страница 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Страница 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Страница 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Страница 456: ......
Страница 462: ......
Страница 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Страница 524: ......
Страница 526: ......
Страница 556: ......
Страница 558: ......
Страница 560: ......
Страница 597: ......