Section 7. Installation
141
•
After
EndSequence
or an infinite
Scan()
/
NextScan
and before
EndProg
or
SlowSequence
•
Immediately following
SlowSequence. SlowSequence
code starts
executing after any declaration sequence. Only declaration sequences can
occur after
EndSequence
and before
SlowSequence
or
EndProg
.
7.6.3.11.1 Declaring Data Tables
Data are stored in tables as directed by the CRBasic program. A data table is
created by a series of CRBasic instructions entered after variable declarations but
before the
BeginProg
instruction. These instructions include:
DataTable()
'Output Trigger Condition(s)
'Output Processing Instructions
EndTable
A data table is essentially a file that resides in CR800 memory. The file is written
to each time data are directed to that file. The trigger that initiates data storage is
tripped either by the CR800 clock, or by an event, such as a high temperature.
The maximum number of data tables is 253 (prior to OS 28, the limit was 30 data
tables), but the maximum can vary with other programming considerations. If
your need for data tables approaches the maximum, only testing will define your
limit. Data tables may store individual measurements, individual calculated
values, or summary data such as averages, maxima, or minima to data tables.
Each data table is associated with overhead information that becomes part of the
ASCII file header (first few lines of the file) when data are downloaded to a PC.
Overhead information includes the following:
•
Table format
•
Datalogger type and operating system version
•
Name of the CRBasic program running in the datalogger
•
Name of the data table (limited to 20 characters)
•
Alphanumeric field names to attach at the head of data columns
This information is referred to as "table definitions."
Содержание CR800 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 34: ......
Страница 54: ......
Страница 92: ......
Страница 190: ...Section 7 Installation 190 FIGURE 40 Running Average Frequency Response FIGURE 41 Running Average Signal Attenuation ...
Страница 310: ......
Страница 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Страница 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Страница 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Страница 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Страница 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Страница 456: ......
Страница 462: ......
Страница 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Страница 524: ......
Страница 526: ......
Страница 556: ......
Страница 558: ......
Страница 560: ......
Страница 597: ......