2.2. Wiring
•
When performing wiring, check the connector pin and cable
conductor colour when connecting a cable.
Connection of a wrong cable may cause breakage, failure or
malfunction.
•
Check if the wiring is properly insulated.
・
Avoid contacting other circuits, ground faults, and terminal-to-terminal
continuity.
This could an excessive current (short circuit), possibly causing
breakage.
•
Use a rated DC regulated power supply isolated from the commercial
alternating current power source. A non-isolated power supply may
cause electric shock.
With an unregulated power supply, the peak value may exceed the
maximum rating, causing breakage of this product or poor accuracy.
•
Stop the controllers and mechanical equipment and turn the power
off before connecting wiring.
Sudden activation may cause unexpected actions, possibly causing
danger.
First, while leaving controllers and mechanical equipment stopped,
perform a power-on test. Discharge static electricity from human
bodies, tools and equipment before and during work. Connect a
flexible cable, such as the one for robots, to moving parts.
•
Do not exceed the source voltage range during operation. An
excessive voltage or an alternating current power supply (100VAC)
will cause damage or fire.
•
Do not short-circuit the load since this may cause damage or fire.
•
The optional shield cable connector is a shield wire.
・
When not using the wire, insulate so that there is no contact with
other wires (including the shield wire).If missconnecting wires to the
ground, it will lead to malfunction or destroy the product.
!