4.
OPERATION METHOD
•
This product does not conduct pressure control during around two
seconds while carrying out self diagnosis immediately after it is turned
on. Therefore build a control circuit or program to ignore signals for
about two seconds immediately after power-on.
•
To change output settings, stop the equipment to avoid unintended
actions caused to the equipment in the control system.
4.1.
Name and Function of Display/Operation Part
Output display (red)
“F” is displayed during function setting.
“-” is lit when the switch output is ON.
(Only for switch output specification)
* The bar blinks upon detection of an
excessive current (short circuit).
“E” lights when error output is ON.
* The letter blinks upon detection of
an excessive current.
* If there is an upper or lower limit in the function setting,
one of the following is displayed.
or
key
Use the key to start various setting
modes.
Use the key to set a value during data
entry.
key
Use the key to select the digit to be changed
during data entry.
3-digit numerical LED display (green)
In the RUN mode (pressure display), the pressure or
function setting data is displayed.
* In the function setting data display mode, the setting
mode number and setting are displayed.
During data entry, a value or other types of data are
displayed.
Upon error display, the error code number is displayed.
< During pressure display > < During setting display >
< Error output display>
key
Use the key in the RUN mode
(pressure display), to display various
settings one by one.
Use the key to select a setting item
during data entry.
Use the key to increase/change the
value or the like during data entry.
!
CAUTION
:
Code number
Setting
method
Setting mode
number