29
46. Lay on the fifth fire clay ring and
adjust the rotary chimney direction by turning.
47. Lay on final fire clay ring with connection to
ceiling.
We recommend sealing all connecting joints with
acrylic adhesive and coating the entire system. Suita-
ble paints are, for example, indoor silicate paints (e.g.
Brillux), clay plaster and clay paints. Specialized paint
dealers or professional painters can advise you locally.
18.3 Continuation of installation of S21 GO-Line with ceiling connection
48. Remove all components (with the exception of
the floor panel) again while marking and drilling
the connections (fireplace connection)
Connections:
Flue gas connector Ø 160 mm:
Centre the system connection relative to the ceiling.
Distance from the wall (including 100 mm wall
distance) = 408 mm
External air connection Ø 125 mm:
Connection height from upper edge of finished floor (OKFF)
to centre of connection = 165 mm
Outside air
connection
165 mm
To obtain a fine-grained surface, mix some of the re-
pair compound into the paint. If necessary, then paint
over the system again only with paint.
408 mm
Wall